METHOD B -
factory-built Solid-Pak chimney section with insulation
of the chimney length and wall combustibles. Use sheet
metal supports fastened securely to wall surfaces on
fastening supports to chimney length, do not penetrate the
The inner end of the Solid-Pak chimney section shall be
sealed with a non-water soluble refractory cement. Use
this cement to also seal to the brick masonry penetration.
METHOD C -
Wall Member: Starting with a minimum 24 gage (.024"
minimum 24 gage ventilated wall thimble which has two
surface of the wall thimble to wall combustibles. Support
the wall thimble, and cover its opening with a 24-gage
the metal chimney connector. See that the supports are
fastened securely to wall surfaces on all sides. Make sure
fasteners used to secure the metal chimney connector do
© 2023 United States Stove Company
METHOD D -
Member: Start with a solid-pak listed factory built chimney
this as a pass-through for a minimum 24-gauge single
connector by way of sheet metal support plates at both
ends of chimney section. Cover opening with and support
chimney section on both sides with 24 gage minimum
sheet metal supports. See that the supports are fastened
securely to wall surfaces on all sides. Make sure fasteners
liner.
• Connectors to a masonry chimney, excepting method B,
shall extend in one continuous section through the wall
pass-through system and the chimney wall, to but not
• A chimney connector shall not pass through an attic or
or ceiling.