4. Strip the insulation of L, N and the grounding conductor 10mm.
5. In the case of fine stranded wire L, N and PE are to be fitted with bootlace ferrules.
6. Disassemble the AC connector and connect the conductors to the AC connector.
7.
Ensure that all conductors are securely connected to the AC connector, assemble the AC
connector.
8. Plug the grid connector into the socket for the grid connection. When doing so, align the
grid connector so that the key on the inverter grid socket is inserted into the keyway on the
grid connector bush insert.
9. For backup connection, plug the backup connector into the inverter backup socket and
tighten clockwise firmly.
To connect the grid connector:
1.
Stripping 14mm
PE
L N
14mm
30mm
Please ensure connector has been correctly installed.