TECHNICAL DATA
Drilling capacity in steel ...........................................................
Drilling capacity in wood ..........................................................
Wood screws (without pre-drilling) ..........................................
No-load speed, 1st gear ..........................................................
No-load speed, 2nd gear .........................................................
Torque
Low torque*1 ........................................................................
High torque*1 ........................................................................
Static jamming moment, 1st gear/2nd gear *1 .....................
Screwing capacity with one fully charged battery (2 Ah) : *2
5x40 Soft wood ....................................................................
Battery voltage.........................................................................
Drill opening range ..................................................................
Weight according EPTA-Procedure 01/2003 ...........................
Noise/vibration information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level ................................................................
Wear ear protectors!
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
h
Drilling into metal ..................................................................
Uncertainty K= ......................................................................
Screwing ...............................................................................
Uncertainty K= ......................................................................
*1 Measured according to Milwaukee norm N 877318
*2 The values stated are reference values.
Actual values might differ, depending on the material and
quality of the screws.
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing
loss.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring. Cutting accessory contacting
a live" wire may make exposed metal parts of the power tool
live" and shock the operator.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes
and apron.
Sawdust and splinters must not be removed while the
machine is running.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
Remove the battery pack before starting any work on the
machine.
16
ENGLISH
PLD 12 X
PLD 14.4 X
...........................13 mm ..........................13 mm
...........................31 mm ..........................33 mm
.............................8 mm ..........................10 mm
......................0-380 min
-1
....................0-400 min
-1
....................0-1250 min
-1
..................0-1400 min
-1
...........................18 Nm ...........................21 Nm
...........................38 Nm ...........................44 Nm
......................32/15 Nm ......................35/16 Nm
.............................390 ...............................460
...........................12 V ...........................14,4 V
.....................1,5-13 mm ....................1,5-13 mm
..........................2,0 kg ............................2,2 kg
...........................79 dB (A) ......................79 dB (A)
...........................90 dB (A) ......................90 dB (A)
.......................< 2,5 m/s
......................< 2,5 m/s
2
2
..........................1,5 m/s
.........................1,5 m/s
2
2
.......................< 2,5 m/s
......................< 2,5 m/s
2
2
..........................1,5 m/s
.........................1,5 m/s
2
2
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors offer to
retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only System PBS 3000 chargers for charging System
PBS 3000 battery packs. Do not use battery packs from
other systems.
No metal parts must be allowed to enter the battery section
of the charger (short circuit risk).
Never break open battery packs and chargers and store
only in dry rooms. Keep dry at all times.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least 10
minutes and immediately seek medical attention.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents.
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 60745-2-2:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
in accordance with the regulations
2011/65/EU (RoHs)
2006/42/EC
2004/108/EC
Winnenden, 2012-11-12
Rainer Kumpf
Director Product Development
Authorized to compile the technical file
SPECIFIED CONDITIONS OF USE
The battery screwdriver is designed for drilling and
screwdriving for independent use away from mains supply.
Do not use this product in any other way as stated for
normal use.
ADVICE FOR OPERATION
The gears can be only changed when the machine is
switched off.
BATTERIES
New battery packs reach full loading capacity after 4 - 5
chargings and dischargings. Battery packs which have not
been used for some time should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
MAINTENANCE
Use only Milwaukee accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our Milwaukee service
agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully
before starting the machine.
Accessory - Not included in standard
equipment, available as an accessory.
Remove the battery pack before starting
any work on the machine.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national
law, electric tools that have reached the end
of their life must be collected separately and
returned to an environmentally compatible
recycling facility.