Télécharger Imprimer la page

Dustcontrol DC 2800c Autostart Manuel D'instruction page 10

Masquer les pouces Voir aussi pour DC 2800c Autostart:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Service
During cleaning and service of the unit, the unit should
be disconnected from the power supply.
Th e fi ne fi lter should be changed at least once per year.
Use only original parts for replacement. If the unit
is equipped with a HEPA fi lter, this fi lter should be
changed every 300 working hours. Use breathing pro-
tection and perform this operation in a contained area.
Th e used fi lter should be placed in containment and
disposed of in the proper and prescribed method.
Filter change:
Remove the motor head. Lift the fi lter straight up out
of the cyclone. When required, a plastic sack can be
placed over the cyclone for dust-free fi lter change. Th e
fi lter is lifted directly into the sack.
During the fi lter change, check the fi lter gasket. A da-
maged gasket can allow the release of hazardous dust.
Never use old gaskets or after-market fi lters. Use only
genuine Dustcontrol spare parts to maintain the unit
for use on hazardous dusts.
Check regularly that the electrical cable is not dama-
ged. Th e DC 2800c Autostart should be performance
tested at least once per year because it may be used with
hazardous materials. Worn parts must be replaced.
Filterchange HEPA fi lter:
1.
2.
Part No. 42027
4.
5.
7.
All manuals and user guides at all-guides.com
For vacuum motor the typical average life of the ori-
ginal brushes is 600 - 700 hours. Th ey can then be
exchanged or complete motor/fan replaced. For 2nd
brush set life is ca. 400 hours and for 3rd brush set ca.
300 hours. After that the commutator is worn out and
the motor needs to be replaced.
3.
6.
DC 2800c Autostart, 10
Part No 94116

Publicité

loading

Ce manuel est également adapté pour:

94116