Wiring
Battery
cable included (aj 1000-1300 : 2x16mm
2
/2m) / (aj 2100-2400 : 2x25mm
• black : negative pole (-)
• red : positive pole (+)
M8
Protection device (battery fuse included)
• aj 1000-12: 125A / aj 1300-24: 100A
• aj 2100-12: No fuse** / aj 2400-24: 150A
8
jt8* remote
control module
(accesory)
cable included RJ11 6p, 10m
Remote ON/OFF button
(see p.13 for functions)
2
/2.3m)
* on request
** external fuse required (200A)
AC output
L
cable included (3x1.5mm
2
/ 1m)
• yellow-green : ground / brown : phase /
blue : neutral
solar* PV (s models)
cable included only in aj 2100-12, aj 2400-24 (2x6mm
• black : negative pole (-) / red : positive pole (+)
Protection device (solar fuse included)
• aj 1000-12, aj 1300-24: 25A
• aj 2100-12, aj 2400-24: 30A
The device must be installed in accordance with local standards and regulations in force.
EN
L'appareil doit être installé conformément aux normes et réglementations locales en vigueur.
FR
Das Gerät muss gemäß den geltenden örtlichen Normen und Vorschriften installiert werden.
DE
El dispositivo debe instalarse de acuerdo con las normas y regulaciones locales vigentes.
ES
Standby
2W (1-20W)
N
2
)
9