SURVEILLANCE MODE
To get into this mode, repeatedly press the button MODE (M) to see the image below on
display.
When pressing MODE button, the mode will change in the sequence (AUTO,
SURVEILLANCE, MANUAL, AUTO, SURVEILLANCE...).
In this mode the HUMIDITY button (H) is active to select the desired threshold.
Remote control
In this mode both humidity and twilight sensors are active, the units will be normally in
stand-by with front panel closed, so that when the humidity level in the room exceeds the
set threshold the units start running in extraction.
Hereinafter explaining how the units run in different situations with related operating mode:
In standard humidity (or CO
closed and the sensors active.
In case of humidity (or CO
the medium speed.
In case of humidity (or CO
the night speed.
The units get into humidity alarm when the MASTER unit detects in the room a humidity
level higher than the set threshold among the three values available (40%, 60%, 75%).
* The CO
value will be detected only if you have a control panel with an integrated CO
2
sensor.
Advice for use
Recommended mode when heat recovery is not needed but essential to have a
proper ventilation in the room because of humidity (or CO2).
Typical use in holiday homes since heat recovery is not needed and just a proper
ventilation is essential to prevent air stagnation in the premises.
*) conditions the units are in stand-by with the front panel
2
*) alarm conditions during the day the units run in extraction at
2
*) alarm conditions during the night the units run in extraction at
2