For configuration, please follow the instructions below, taking into consideration that the
first unit installed will be the MASTER and all the others in sequence SLAVE OPPOSITE
to MASTER and SLAVE SAME AS MASTER UNIT.
WARNING: the MASTER is the only unit receiving commands from control device, that will
detect the ambient conditions through the sensors and thus controlling all the system.
If you have a remote panel with CO
control panel.
In case of large indoor space or systems on multi-floors, it is recommended to split the
system into zones (living area-sleeping area or 1
units.
After setting the single units, it is necessary to create one coding common to all the
systems so that the units interact among them avoiding any interference with adjacent
systems.
In the scheme below see the 6 dip switches 0/1 needed to create one coding for each
system.
WARNING: factory setting of dip switches is 0 (OFF), thus recommended to set on 1 (ON)
at least one of the dip switches to uniquely codify the system.
sensor, the CO
2
2
st
floor-2
57
will be detected directly by the
nd
floor) for easier control of the

Publicité