4.3
Product specification
The TST RFUxK2-E is an accessory of the company FEIG ELECTRONIC GmbH
and provides the following functions:
•
6 inputs, 6 relay outputs, 1 digital output, 1 CAN interface and 1 RS-485
interface.
•
All functions are adjustable by parameter via the controller.
4.3.1
Intended use
ATTENTION
TST RFUxK2-A and TST RFUxK2-E cannot be operated in parallel.
The expansion board serves as input and output extension for serial interfaces and
detectors.
The expansion board can be operated with the real text display TST KKTA.
If the TST RFUxK2-A or TST RFUxK2-E is connected to the
CAN(0) interface inside the housing, the TST RFUxK2-F can
be operated in parallel.
Parallel operation of several TST RFUxK2 boards via the
other CAN interfaces is not possible!
Operation is only permitted with the following controllers:
CE
TST FUF2-A, -C, -F Series
TST FU3F-AU, -CU, -FU Series
TST FU3F-A,-C, -F Series
TST FUZ2-B Series
TST FUZ2-CX, -L, -P, -S Series
4.4
Technical data for Europe
Dimensions (LxWxH)
166 x 115 x 30 mm
Operation
-20 °C to +65 °C
Temperature
Storage
-20 °C to +70 °C
Weight
ca. 290 g
Equipment type
Input and output expansion board
Protection type
IP 00
Protection class
--
Supply voltage
24 VDC ± 20 %
Power consumption
max. 8 W
Current carrying capacity
max. 0.7 A (@ Ta = 65 °C)
max. 1.1 A (@ Ta = 23 °C)
Controller
Connection/interface
Other
X33 (IN 21), X34 (IN 23),
X36 (IN 24 – IN 26)
The 24 V outputs and transistor outputs are electronically fused and may
be loaded with max. 1.1 A (@23 °C) (resistive loads only)!
Relays OUT 5 – OUT 8
Relays OUT 9 – OUT 10
Relay contact (general)
UL
Digital output
Connection
X31
310-319
X32
320-325
X33
330-335
X34
340-342
X36
360-363
X38
380-385
X39
390-393
Machinery Directive: 2006/42/EC
Low Voltage Directive: 2014/30/EU
Harmonised standards applied:
EN 60335-1:2012 / AC:2014
Section: Chapters 7, 10, 11, 13, 14, 16, 17, 19, 22, 23, 24, 29 and 30
EN 60335-2-103:2015
Section: Chapters 7, 10, 11, 13, 14, 16, 17, 19, 22, 23, 24, 29 and 30
EN 61000-6-1:2007 Section: Table 1 item 1.5, Table 2, Table 4 items 4.4 + 4.5
EN 61000-6-2:2005 / AC:2005
Section: Table 1 item 1.5, Table 2, Table 4 items 4.4 + 4.5
TST RFUxK2-E
TST_RFUxK2-E_Install_rev4_mul
System interface (internal connection to the
controller),
1x CAN as external interface,
1x RS 485 as external interface
4-times seven-segment display (red), optional
2x 16 characters plain text display
Inputs
24 VDC / typ.15 mA, max. 26 VDC / 20 mA
Outputs
Normally open contact with common COM
port.
Max. 230 VAC / 3 A in total are allowed.
Changeover contact free of potential.
The same switching voltage must be used
for both relays!
max. 230 VAC / 3 A, min. 10 mA. Once relay
contacts have been used for power switching,
they can no longer switch very small currents!
OUT 11: 1 x 24 V / min. 10 mA / max. 100 mA,
normally open, +24 V switching!
Cable size
Tightening
flexible with wire
torque
rigid
end ferrule
0,2 - 2,5 mm²
0,25 - 1,5 mm²
0,35 - 0,4 Nm
0,2 - 2,5 mm²
0,25 -1,5 mm²
0,35 - 0,4 Nm
0,2 - 1,5 mm²
0,25 - 0,75 mm²
0,22 - 0,25 Nm
EC installation declaration
6 | 10
Lange Straße 4 | D-35781 Weilburg
Tel. +49 6471 3109-0 | Mail:
4.5
UL-Ratings
Supply
24 VDC / max. 1 a, Class 2 (X30a)
Class 2 output
24 VDC / max. 700 mA
Maximum surrounding
65 °C
air temperature
Degree of pollution
For use in an environment with pollution degree 2.
Battery
--
X38
CAN interface (PIN 381, 382):
24 VDC / max. 20 mA, Class 2
Output (Pin 380):
24 VDC / max. 0.7 A
X39
RS-485 interface (PIN 391, 392):
24 VDC / max. 20 mA, Class 2
Output (Pin 390):
24 VDC / max. 0.7 A
X33
Input 21, 22; 24 VDC each / max. 20 mA, Class 2
Digital Output; 24 VDC (Pin 333) / max. 200 mA,
Class 2
Output (Pin 330); 24 VDC / max. 0.7 A
X34
Input 23; 24 VDC / max. 20 mA, Class 2
Output (Pin 340); 24 VDC / max. 0.7 A
X36
Input 24, 25, 26; 24 VDC each / max. 20 mA,
Class 2
Output (Pin 360); 24 VDC / max. 0.7 A
X37 / X37a
Foil key pad connection
X30a
Power Supply Input; 24 VDC / max. 1 A
X40
CAN-Bus (internal connection to the controller,
non-isolated)
X300
Programming interface, internal (for reference
only)
X400 / X400a
Connector for display; 5 VDC, 200 mA
X700
Anybus interface; 24 VDC / typ. 100 mA, Class 2
(for reference only)
1
Note: The maximum load of all Class 2 outputs shall not exceed 0.7 A in any
combination.
FEIG ELECTRONIC GmbH
info@feig.de
1
, Class 2
1
, Class 2
1
, Class 2
1
, Class 2
1
, Class 2
1
, Class 2
2019-10-15