11.2 Electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with national and regional regulations.
WARNING Electrocution
In the case of a permanent connection, ensure the ap-
pliance can be separated from the power supply by an
isolator that disconnects all poles with at least 3 mm
contact separation.
WARNING Electrocution
Ensure that the appliance is connected to the ground
conductor.
Property damage
!
Observe the type plate. The specified voltage must match
the mains power supply.
Property damage
!
When making the connection to a standard safety
socket (in the case of a power cable with mains
plug), ensure that the socket is freely accessible after
the appliance has been installed.
14
| Ultronic
Plus & Premium Hand Dryers
The power supply can be connected directly to the appliance or
via a power cable with mains plug.
2
N
L
1 Cable entry
2 Cable duct
Note
Make sure the length of the power cable is sufficient
to pass correctly through the wall mounting bracket
to the terminal.
Route the power cable from the back through the cable
grommet of the wall mounting bracket.