If the protection meets the requirements at extremes of temperature (-5°C
to +55°C) the marking is completed with the letter T. Additional markings
on the product refer to other standards.
FUNCTIONS
On/Off
To activate the welding fi lter, press the ON/SHADE button. The welding
fi lter automatically turns OFF after 1 hour of inactivity.
The welding fi lter has two photo sensors (see fi g A:2) that react independently
and cause the fi lter to darken when a welding arc is struck. The welding
fi lter may not go to dark position if the sensors are blocked or the welding
arc is totally shielded.
Flashing light sources (e.g. safety strobe lights) can trigger the welding
fi lter making it fl ash when no welding is occurring. This interference can
occur from long distances and/or from refl ected light. Welding areas must
be shielded from such interference.
Shade
Models Speedglas 100S-10 and Speedglas 100S-11 have a fi xed dark
shade where no setting is required.
Model Speedglas 100V has selectable dark shade settings. Five different
Shade Number settings, 8-12, are available in the dark state. In order to
see the current Shade Number setting, momentarily press the ON/SHADE
button. To select another Shade Number, press the ON/SHADE button
repeatedly while the LED indicators on the display are fl ashing. Move the
fl ashing LED to the desired Shade Number.
In all welding processes the arc should only be viewed with the
recommended dark shade. See table page 210.