9.2 Control board
9.2.1 Hydraulic module board
1
29
28
27
26
Order
Port
Code
1
POWER
CN21
2
CN5
GND
PUMP
3
CN28
4
CN25
DEBUG
5
/
S1,S2,S3,SW9
6
CN4
USB
7
CN33
/
8
CN8
FS
T2
T2B
9
CN6
TW_in
TW_out
T1
10
CN24
Tbt
11
CN23
RH
13
CN37
Pw
14
CN15
Tw2
K1 K2
17
CN66
S1 S2
18
CN27
HA/HB
2
3
4
CN5
CN28
CN21
CN25
CN32
S1
CN29
S3
CN42
CN22
1
2
3
4
5
6
7
13
14 15
16
17
18
19
CN11
25
Assembly unit
Port for power supply
Port for ground
Port for variable speed pump power input
Port for IC programming
Dip switch
Port for USB programming
Port for breathing light
Port for flow switch
Port for refrigerant liquid side
temperature (heating mode)
Port for temperature sensors of refrigerant gas
side temperature (cooling mode)
Port for temperature sensors of inlet water
temperature of plate heat exchanger
Port for temperature sensors of outlet
water temperature of plate heat exchanger
Port for temperature sensors of final
outlet water temperature
Port for temperature sensor of balance tank
Port for humidity sensor
Port for temperature sensor of water pressure
Port for outlet water for zone 2 temp. sensor
Input port (Reserved)
Reserved
Port for communication with the
HOME BUS wired controller (Reserved)
5
6 7
8
9
CN8
CN6
CN15
S2
CN33
CN4
SW9
8
9
10
11
12
20
21
22
23
24
Order
Port
Code
10V GND Output port for 0-10V
HT
Control port for room thermostat (heating mode)
19
CN31
COM
Power port for room thermostat
CL
Control port for room thermostat (cooling mode)
Port for smart grid (grid signal)
SG
20
CN35
EVU
Port for smart grid (photovoltaic signal)
Port for remote switch
M1 M2
21
CN36
T1 T2
Port for thermostat transfer board
22
CN17
PUMP_BP
Port for variable speed pump communication
Communicate port between indoor
CN19
23
P Q
unit and outdoor unit
3 4
Port for communication with the wired controller
Communicate port between hydraulic
24
CN30
6 7
module board and main control board
Port for Internal machine Cascade
9 10
Port for additional heat source
1 2
3 4 17
Reserved
5 6 18
Port for SV2(3-way valve)
7 8 19
Port for SV3(3-way valve)
9 20
Port for zone 2 pump
25
CN11
10 21
Port for outside circulation pump
11 22
Reserved
12 23
Reserved
13 16
Reserved
14 16
Control port for internal backup heater 1
15 17
Control port for internal backup heater 2
24 23
Output port for alarm/Defrost run
Control port for internal backup heater 1
IBH1
26
CN22
IBH2
Control port for internal backup heater 2
TBH
Reserved
27
CN42
HEAT6
Port for anti-freeze electric heating tape(internal)
28
CN29
HEAT5
Port for anti-freeze electric heating tape(internal)
29
CN32 AC OUT Port for backup heater
18
10
11
CN24
CN23
13
CN37
14
CN64
CN27
17
CN66
18
19
CN31
20
CN35
21
CN36
22
CN17
23
1
2
3
4
5
6
7
8
9
10
CN30
24
Assembly unit
V.1

Publicité

loading

Produits Connexes pour Johnson ICEBERG Serie