Télécharger Imprimer la page

Johnson ICEBERG Serie Manuel D'instructions page 102

Publicité

Les langues disponibles

Les langues disponibles

11.1 Setting parameters
The parameters related to this chapter are shown in the table below.
Order
Code
number
2.1
COOL MODE
t_T4_FRESH_C
2.2
2.3
T4CMAX
2.4
T4CMIN
2.5
dT1SC
2.6
dTSC
2.7
t_INTERVAL_C
2.8
T1SetC1
2.9
T1SetC2
2.10
T4C1
2.11
T4C2
2.12
ZONE1 C-EMISSION
2.13
ZONE2 C-EMISSION
3.1
HEAT MODE
3.2
t_T4_FRESH_H
3.3
T4HMAX
3.4
T4HMIN
3.5
dT1SH
3.6
dTSH
3.7
t_INTERVAL_H
3.8
T1SetH1
3.9
T1SetH2
3.10
T4H1
3.11
T4H2
3.12
ZONE1 H-EMISSION
3.13
ZONE2 H-EMISSION
3.14
FORCE DEFROST
4.1
T4AUTOCMIN
4.2
T4AUTOHMAX
5.1
WATER FLOW TEMP.
5.2
ROOM TEMP.
5.3
DOUBLE ZONE
State
Enable or disable the cooling mode:0=NON,1=YES
The refresh time of climate related curves for cooling mode
The highest ambient operation temperature for cooling mode
The lowest ambient operating temperature for cooling mode
The temperature difference between T1 and T1S(the
set water temperature) for starting the heat pump.
The temperature difference between actual
room temperature Ta and the set room
temperature Tas for starting the heat pump.
The start time interval of the compressor in cooling mode
The setting temperature 1 of climate related
curves for cooling mode.
The setting temperature 2 of climate related
curves for cooling mode.
The ambient temperature 1 of climate related
curves for cooling mode.
The ambient temperature 2 of climate related
curves for cooling mode.
The terminal type of zone 1 for cooling mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
The terminal type of zone 2 for cooling mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
Enable or disable the heating mode
The refresh time of climate related curves for heating mode
The maximum ambient operating temperature for heating mode
The minimum ambient operating temperature for
heating mode
The temperature difference between T1 and T1S(the
set water temperature) for starting the heat pump
The temperature difference between actual
room temperature Ta and the set room
temperature Tas for starting the heat pump
The start time interval of the compressor in heating mode
The setting temperature 1 of climate related
curves for heating mode
The setting temperature 2 of climate related
curves for heating mode
The ambient temperature 1 of climate related
curves for heating mode
The ambient temperature 2 of climate related
curves for heating mode
The terminal type of zone 1 for heating mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
The terminal type of zone 2 for heating mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
Enable or disable the FORCE DEFROST
function:0=NON,1=YES
The minimum operating ambient temperature
for cooling in auto mode
The maximum operating ambient temperature
for heating in auto mode
Enable or disable the WATER FLOW TEMP.:0=NON,1=YES
Enable or disable the ROOM TEMP.:0=NON,1=YES
Enable or disable the ROOM THERMOSTAT
DOUBLE
ZONE:0=NON,1=YES
41
Default
Unit
1
/
0.5
hours
52
°C
10
°C
5
°C
°C
2
5
min
°C
10
°C
16
°C
35
25
°C
0
/
/
0
/
1
0.5
hours
°C
25
°C
-15
5
°C
2
°C
5
min
35
°C
28
°C
-5
°C
°C
7
1
/
2
/
0
/
25
°C
17
°C
1
/
0
/
0
/
V.1

Publicité

loading

Produits Connexes pour Johnson ICEBERG Serie