IMPORTANT:
The power supply to the appliance must be cut off before any
adjustments or maintenance work is done on it. Air duct is
supposed to use in ventilation.
This oven is dual rated, designed to be connected to either
208/240V AC, 60Hz, 3-wire, two-phase power supply.
The electrical supply should be 3-wire two-phase AC. Install a
suitable conduit box (not furnished).
An appropriately sized, U-listed
conduit connector must be used to
correctly attach the 4-WIRE
BRANCH CIRCUIT Refer to Figure
B: conduit to the junction box.
3-WIRE BRANCH CIRCUIT
Grounded Neutral
Cable from Power Supply
Red Wires
White or Gray Wire
Green Wire
Cable from Oven
14
CIRCUIT REQUIRED
208V, 60Hz
240V,60Hz
12 AMP
15 AMP
Figure 5
junction box
Black Wires
UL Listed Conduit
Connector
Refer to Figure 5. Where local codes allow the connection of
green ground wire from the oven to the branch circuit white neutral
wire (gray or white colored wire):
• If local codes permit, connect the green ground wire from the
oven to the branch circuit neutral wire (gray or white colored wire).
• Connect the red and black leads from the oven to the
corresponding leads in the junction box.
4-WIRE BRANCH CIRCUIT
Refer to Figure B:
• Disconnect ground from neutral at free end of conduit.
• Connect the green ground wire from the oven to the ground wire
in the junction box (bare or green colored wire).
• Connect the red and black leads from the oven to the
corresponding leads in the junction box.
Ungrounded Neutral
Cable from Power Supply
Red Wires
Bare or
Green Wire
Cable from Oven
Figure 6
White Wire
Junction box
Black Wires
UL Listed Conduit
Connector