INSTALLATION

2-1 Mounting locations

1
Install the master monitor station in a place
where the screen is not exposed to direct
sunlight.
2-2 Wiring method, wiring distance
Wire the units from station-to-station (daisy-chained).
JK-DA
JK-DV
JK-DVF
2
B
PS-1820
PS18
PS-1810DIN
PS-1820DIN
2-3 Cable
1
Use PVC jacket with PE (polyethylene) insulated cable
2
Never use individual conductors, twisted pair cable or coaxial cable.
2
The master monitor station has switches on
both sides. Allow at least 5 cm (2") of open
space on either side.
A
JK-1HD
JK-1MED
4
C
IER-2
(x2)
3
JK-1MED
2
+ 5 cm
+ 5 cm
(2")
(2")
JK-1SD
Ø 0,65 mm
A
50 m
B
5 m
C
75 m
3
When using a cable with unused conductors, terminate both ends of
the unused pair(s) with a 120 Ω resistor.
JK-1MED
A1
A2
S
S
B1
B2
L
L
+
-
120
- 3 -
Allow at least 15 cm (6") of vertical open
space from the center of the mounting
bracket in order to mount the master
monitor station.
3
+ 15 cm
(6")
22 AWG
Ø 1,0 mm
18 AWG
165'
100 m
330'
16'
10 m
33'
245'
150 m
490'
JK-1HD/JK-1SD
B1
B2
SW
SW
+
-
120

Publicité