Télécharger Imprimer la page

Qlima DFA 2320 Manuel D'utilisation page 2

Publicité

Les langues disponibles

Les langues disponibles

TABLE DES MATIÈRES
3
Conseils d'utilisation (fr)
Montage du chauffage
Installation
Remplissage du reservoir
Allumer et faire fonctionner
de l'appareil
Schéma de câblage
Dépannage
Maintenance
Instructions de stockage
Conditions de garantie
Protection de l'environnement
TABLE OF CONTENTS
4
Directions for use (gb)
Assembling the heater
Installation instructions
Filling fuel
Igniting and operating the heater
Wiring diagram
Trouble shooting
Maintenance
Storage instructions
Guarantee conditions
Environmental protection
INHOUDSOPGAVE
1
Gebruiksaanwijzingen
De kachel monteren
Installatie
Vullen met brandstof
De heater starten en gebruiken
Bedradingsschema
Problemen oplossen
Onderhoud
Aanwijzingen voor bewaring
Garantievoorwaarden
Milieubescherming
3
2
2
SPECIFICATIONS DUAL FUEL FORCED AIR HEATER
SPECIFICATIONS DUAL FUEL FORCED AIR HEATER
Model
Model
DFA 1650 Premium
DFA 2320
P
220-230V / 50hz / 1Ph
Pin
220-240V / 50hz / 1Ph
in
Ignition
Oil consumption
Normal operation
Normal operation
Fuel
Combustible liquide conforme aux arrêtes
Fuel
Diesel/Kerosene
du 25/06/2010 et 18/07/2002 or Class C1 paraffin
Q
(BS2869 part2) or 1-K kerosene or No.1. fuel oil
20,000 W
N
P
IP class
out
IP class
Serial number
PVG Holding BV, Kanaalstraat 12 C, 5347 KM Oss, the Netherlands
PVG Holding BV, Kanaalstraat 12 C, 5347 KM Oss, the Netherlands | P.O.
P.O. Box 96, 5340 AB Oss, the Netherlands | Qlima.com
Box 96, 5340 AB Oss, the Netherlands | Qlima.com
Made in PRC
Made in Korea
More
Info:
SPECIFICATIONS DUAL FUEL FORCED AIR HEATER
SPECIFICATIONS DUAL FUEL FORCED AIR HEATER
Model
DFA 2330
Model
DFA 1650 Premium
P
220-230V / 50hz / 1Ph
Pin
220-240V / 50hz / 1Ph
in
Ignition
Oil consumption
Normal operation
Normal operation
Fuel
Combustible liquide conforme aux arrêtes
Fuel
Diesel/Kerosene
du 25/06/2010 et 18/07/2002 or Class C1 paraffin
Q
30,000 W
(BS2869 part2) or 1-K kerosene or No.1. fuel oil
N
P
IP class
out
IP class
Serial number
PVG Holding BV, Kanaalstraat 12 C, 5347 KM Oss, the Netherlands
PVG Holding BV, Kanaalstraat 12 C, 5347 KM Oss, the Netherlands | P.O.
P.O. Box 96, 5340 AB Oss, the Netherlands | Qlima.com
Box 96, 5340 AB Oss, the Netherlands | Qlima.com
Made in PRC
Made in Korea
More
Info:
SPECIFICATIONS DUAL FUEL FORCED AIR HEATER
SPECIFICATIONS DUAL FUEL FORCED AIR HEATER
Model
DFA 2350
Model
DFA 1650 Premium
P
220-230V / 50hz / 1Ph
Pin
220-240V / 50hz / 1Ph
in
Ignition
Oil consumption
Normal operation
Normal operation
Fuel
Combustible liquide conforme aux arrêtes
Fuel
Diesel/Kerosene
du 25/06/2010 et 18/07/2002 or Class C1 paraffin
Q
50,000 W
(BS2869 part2) or 1-K kerosene or No.1. fuel oil
N
P
IP class
out
IP class
Serial number
PVG Holding BV, Kanaalstraat 12 C, 5347 KM Oss, the Netherlands
PVG Holding BV, Kanaalstraat 12 C, 5347 KM Oss, the Netherlands | P.O.
P.O. Box 96, 5340 AB Oss, the Netherlands | Qlima.com
Box 96, 5340 AB Oss, the Netherlands | Qlima.com
Made in PRC
Made in Korea
More
Info:
145 W
1.65kg/h
125 W
230 W
q
16.500 W
IPX4
w
IPX4
e
r
t
y
u
145 W
2.5kg/h
125 W
230 W
q
16.500 W
IPX4
IPX4
w
g
d
r
h
145 W
4kg/h
t
125 W
340 W
y
16.500 W
IPX4
IPX4
1 LISEZ PRÉALABLEMENT LE MANUEL D'UTILISATION.
2 EN CAS DE DOUTE, CONTACTEZ VOTRE REVENDEUR.
DFA 2320
DFA 2330
DFA 2350
PRINCIPAUX
COMPOSANTS
Sortie de l'air chaud
q
Coque inférieure
w
Réservoir de
e
i
combustible
o
Affichage de la
r
a
température
s
Bouton de réglage
t
de la température
d
Affichage de la
y
f
température
g
Interrupteur
u
d'alimentation/
réinitialisation à LED
Poignée
i
Coque supérieure
o
o
Grille de protection
a
du ventilateur
j
Compresseur d'air
s
a
Bouchon du
d
réservoir de
s
combustible
Cordon
f
f
d'alimentation
e
Jauge de niveau
g
k
d'huile
u
Roue
h
Tube supérieur
j
Tube inférieur"
k
3
3
3

Publicité

loading

Ce manuel est également adapté pour:

Dfa 2330Dfa 2350