Télécharger Imprimer la page

Danfoss TP7000-RF Instructions D'installation page 5

Thermostat d'ambiance programmable 7 jours
Masquer les pouces Voir aussi pour TP7000-RF:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
7-day - each day can be programmed with different times and
temperatures.
5/2 day - one set of times & temperatures for weekdays, and
another set for weekends.
Optimum start control - function which switches the heating on
earlier than the Event 1 programmed time to ensure the required
temperature is achieved by the set time.
Chrono-proportional control - energy saving feature which
fi res the boiler at regular intervals to maintain a set temperature,
achieving a constant ambient environment for the user.
For a full explanation of all advanced features please visit
our website www.danfoss-randall.co.uk or call 01234 364621
to obtain a copy of our Advanced Features Guide.
Setting Optimum Start Control
J
Set Sw2 to OSC ON (see
DIL settings page 4)
J
Select OPTIMISER CURVE
in programming mode
A - Event 1 Set Point
B - Deviation from Set Point
C - Switch On Time prior to
Event
D - Optimiser Curve Setting
TP7000 Wiring (not RF models)
2
1
COM
ON
M models only
L
ELECTRONICS
3
4
5
OFF
N
A
-1˚C
-2˚C
B
-3˚C
-4˚C
120
90
min.
min.
6
7
REMOTE
SENSOR
'A' models
only
D
30
Event 1
60
min.
time (0)
min.
C
5

Publicité

loading

Ce manuel est également adapté pour:

Tp7000Tp7000mTp7000 + rf