2.2 Mounting With QuickFasten
IMPORTANT
 Observe the mounting dimensions of the VVX
 Observe the dimensions of the inlet
 Only use suitable O-rings
 Observe the flow direction on the device
 Select a suitable location for installation ( 2 "Installation").
To ensure the best possible measuring accuracy, a vertical installation position with in-
creasing flow is preferable (no collecting of dirt deposits).
 Install suitable QuickFasten connections (inlet and outlet) at the installation location.
Mount the O-rings on the VVX and on the inlet.
Put the VVX on the inlet.
Be careful not to damage the O-ring.
Slide the clip over the connection until it snaps into
place.
Put the outlet on the VVX.
Be careful not to damage the O-ring.
Slide the clip over the connection until it snaps into
place.
IMPORTANT
The clip must snap properly.
The webs of the VVX and the inlet or outlet must be lo-
cated in the slots of the clip.