7. K130MA CHARACTERISTICS
TIMER-OPERATED OPENING AND CLOSING CYCLES
The opening/closing of the automation can be controlled by means of a timer that has a free N.O.
output contact (relay). The timer must be connected to terminals 4 - 6 (OPEN/CLOSE button) and can
be programmed so that, at the desired opening time, the relay contact closes until the desired closing
time (when the timer's relay contact opens, enabling the automatic closing of the gate).
Note: the automatic closing function must be enabled by setting Dip-switch no. 1 to ON).
OBSTACLE DETECTION
If the obstacle detection function (adjustable through FR trimmer) is activated during an opening manoeu-
vre, the gate closes approx. 20 cm., if it is activated during a closing manoeuvre, the gate opens all the way .
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
8. DIAGNOSTICS LED
LED - DL1
Apart from highlighting the presence of the battery, LED DL1 displays any mistakes with a series of
pre-set flashes in various colours:
Key:
led always on;
Always on (green):
1 flash every 4 seconds (green):
LED - DL2
The DL2 LED indicates mistakes in the board logic with a series of pre-set flashes in different colours:
Attention: certain warnings/errors are signaled in sync with a series of flashes of the flashing light.
Key:
led always on;
1 flash every 4 seconds
(green):
/
alternate flashing:
(red/green)
alternate fast flashing
/
: (green/orange)
Fast (orange) flashing:
1 (red) flash:
1 (orange) flash:
2 (red) flashes +
main voltage present;
no main voltage; power supply through battery/photovoltaic
panel
Check the main voltage and the fuse F2
led flashing;
normal operation;
saving to be performed;
Update stroke – deceleration points;
See the section "HOW TO CHANGE THE DECELERATION POINTS" in paragraph 6
saving in progress;
phototest error
Disable phototest (dip-switch 6 OFF), check the operation of the photocells
and their connection;
unknown status, next operation REALIGNMENT;
obstacle for motor;
:
Make sure there are no obstacles across the path of the gate and that it slides
smoothly;
With an active automatic closing feature, after the intervention meant to de-
tect the obstacle, the automatic closing is deactivated. A command pulse is
required to carry out the closing;
led flashing;
error signaled by the flashing light;