6
FOTOTEST
MASTER/
7
SLAVE
To carry out the memorization, leave DIP SWITCH 7 on OFF.
WITH LIMIT
SWITCHES:
8
SELECTION
TOWARDS OPENING
WITHOUT LIMIT
8
SWITCHES:
BACK JUMP
To change the position of Dip 8, the power must be disconnected. Once modified, rerun
the SetUp of the stroke
9-10-11
Automation type selection
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
On
On
On
Off
Off
On
Off
Off
IMPORTANT: the type of automation and its parameters are set during the programming
of the stroke ONLY the first time the procedure is carried out (led DL2 flashing red/green
alternately). To change the type it is necessary to perform a "FACTORY RESET" before
starting a new setup procedure.
SENSITIVE
12
EDGE
6. MEMORIZATION PROCEDURE OF THE STROKE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations and check:
- The Input connections: all green DL5, DL6, DL7, DL8 must be on steady.
- The mechanical stops of the automation must be installed and adjusted both in opening and
in closing [see motor instructions].
IMPORTANT: Carry out the first stroke memorization with the RAL trimmer positioned
fully turned counterclockwise (minimum deceleration speed).
On the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-COMM
On
instructions).
enables the standard operation (single motor) or SLAVE mode in the mas-
Off
ter/slave configuration (see T-COMM instructions).
operation for leaf with opening to the left (operator side);
On
Attention: the limit switch LEDs (LFCA and LFCC) are inverted
Off operation for gate with opening to the right (gearmotor side);
once the mechanical stop of the closing maneuver is reached, the automa-
On
tion makes a slight movement in the opposite direction to avoid jamming
between the rack and the pinion. (Editable with TauApp)
Off function deactivated
Dip 11 Automation
Off
T-ONE10B For gates up to 400 kg
Off
T-ONE10B For gates from 600 to 1000 kg
Off
T-ONE8BR (24v)
Off
MASTER-R (24V Opening speed = Closing speed)
On
MASTER18QR
On
MASTER-R (24V)
On
T-ONE8BR (24V Opening speed = Closing speed)
On
MASTER18QR heavy or CANTILEVER
On RESISTIVE SENSITIVE EDGE 8,2 KΩ (terminal No. 10).
NC CONTACT SENSITIVE EDGE ( terminal No. 10).
Off
Note: if not used, keep the DIP in the OFF position and bridge the
terminals 7-10
22