This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF
Aesthetic Effects
Reduction
Requirements
Chlorine Taste/Odor
50% reduction
Particulate Class II*
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5 ***
0.010 mg/L
Lead: @ pH 8.5 ***
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Toxaphene
0.003 mg/L
Carbofuran
0.040 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is essential that operational, maintenance, and filter
■
replacement requirements be carried out for the product to
perform as advertised.
Use replacement filter T2RFWG2, part #4396841.
■
Model T1WG2L: Style 1 – When the filter indicator reads
10%, order a new filter. When the indicator reads 0%, it is
recommended that you replace the filter.
Style 2 – When the filter indicator changes from green to
yellow, order a new filter. When the indicator changes from
yellow to red, it is recommended that you replace the filter.
Style 3 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you
replace the filter.
Style 4 – Press FILTER to check the status of your water filter.
If the filter indicator light is yellow, order a new filter. If the filter
indicator light is red, it is recommended that you replace the
filter.
Model T1WG2: Change the water filter cartridge every 6
months. If the water flow to the water dispenser or ice maker
decreases noticeably before 6 months have passed, replace
the water filter cartridge more often.
*Class II particle size: 1 um to <5 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dus
***Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.
NSF is a registered trademark of NSF International.
®
16
PERFORMANCE DATA SHEETS
Base Grille Water Filtration System
Model T1WG2L/T2RFWG2 Capacity 200 Gallons (757 Liters)
Model T1WG2/T2RFWG2 Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI Standard 42 for
the reduction of Chlorine Taste and Odor, Particulate Class II*; and against NSF/ANSI
Standard 53 for the reduction of Mercury, Benzene, Toxaphene, O-dichlorobenzene,
and Carbofuran.
Average
Influent Challenge
Influent
Concentration
2.0182 mg/L
2.0 mg/L ± 10%
1333333 #/mL
At least
10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
0.1533 mg/L
0.15 mg/L ± 10%
0.1400 mg/L
0.15 mg/L ± 10%
0.0058 mg/L
0.006 mg/L ± 10%
0.0059 mg/L
0.006 mg/L ± 10%
0.0154 mg/L
0.015 mg/L ± 10%
1.7571 mg/L
1.8 mg/L ± 10%
0.015 mg/L
0.015 mg/L ± 10%
0.0819 mg/L
0.08 mg/L ± 10%
Maximum
Average
Effluent
Effluent
0.06 mg/L
0.0536 mg/L
6600 #/mL**
2325 #/mL
Maximum
Average
Effluent
Effluent
0.0005 mg/L
0.0005 mg/L
0.0007 mg/L
0.0006 mg/L
0.0002 mg/L
0.0002 mg/L
0.0005 mg/L
0.0003 mg/L
0.0012 mg/L
0.0006 mg/L
0.0250 mg/L
0.0066 mg/L
0.001 mg/L
0.001 mg/L
0.0400 mg/L
0.0213 mg/
These contaminants are not necessarily in your water supply.
■
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or of
■
unknown quality without adequate disinfection before or after
the system.
Refer to the "Warranty" section for the Manufacturer's name,
■
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
■
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum%
Average%
Reduction
Reduction
97.03%
97.34%
99.51%
99.83%
Minimum%
Average%
Reduction
Reduction
99.67%
99.67%
99.50%
99.57%
96.54%
96.54%
91.57%
94.92%
92.22%
96.34%
98.58%
99.63%
93.3%
93.3%
51.13%
74.00%
City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.85 gpm (3.2 L/min.) @ 60 psi*