Télécharger Imprimer la page

Weber 56576 Manuel De L'utilisateur page 126

Grill au gaz naturel intégré

Publicité

Les langues disponibles

Les langues disponibles

Ventilation
m warninG: Ventilation holes must be provided in the
structure at the top and bottom to provide ventilation in the
event of a gas leak.
Ventilation holes can be located in a low visibility area and should be protected by
screening material to prevent rodents and insects from entering the structure. Air holes
will also help dry moisture.
Note: These drawings are only a reference.
• Cross ventilation must be incorporated in the supporting structure. We recommend a
minimum of 100 square inches (254 square cm) of venting per side.
• Vents should be on two sides of the structure.
• The drawings are for reference only.
• Location of the vents should be from the center, outward.
• Locate the vents at both the bottom of the structure and at the top of the structure.
• The bottom vents should be as close to ground level as possible. Make sure the vent
area is not blocked by interior supports of the structure.
• We recommend vents with screens.
• Access doors to the structure are not considered vents.
• Clean the vents periodically.
m danGer
failure to follow recommended minimum venting
instructions can cause gas to collect in the structure in the
event of a gas leak. this may result in a fire or an explosion
which can cause serious bodily injury or death, and damage
to property.
26
VENTILaTIoN

Publicité

loading

Ce manuel est également adapté pour:

460-ng