ADVANCED OPERATION
HEIDER PRO5 PMR 446
SAVE (Battery Saving)
Heider PRO5 has battery saving feature for a long term transmission. In case the
incoming signal is strong, power output is automatically adjusted to reduce it with
this feature. For instance, there is no need to strong power output to access silencing
in close distances to repetitive station. Automatically activating the battery saving and
low power operation option you have selected ensures that undesirable situations
such as battery leakage are avoided for an efficient communication. In order to
activate battery saving:
1. Push [MENU] button, rotate [CALL] button, switch to MENU [14] SAVE.
2. Adjust the settings after pushing [U/V] button.
3. Adjust SAVE: ON/OFF settings by rotating [CALL] button clockwise or counterclockwise.
4. Push [U/V] button to save the settings adjusted.
5. Push [MENU] or [PTT] buttons to EXIT to normal operation
mode.