S E T T I N G S
PWM MIN AND MAX
This setting has two main purposes. In PWM mode min and max values
specify active dial range. In all other modes it guarantees maximum
pulse ratio. Note: Setting can be used, e.g., to limit maximum heating
power to comply with installation standard EN50599.
VALVE PROTECTION
Valve protection turns heating ON once per week for 5 minutes even at
summer time. This setting is typically used if thermostat controls water
carrier floor heating valve. Feature protects valve during summer time
not to stick.
SENSOR TYPE
Floor sensors from different manufacturers can be used. Supported ty-
pes are 2k, 10k, 12.5k, 15k, 33k NTCs.
LED INTENSITY
Intensity of power and eco touch buttons.
28