EN
NAME OF THERMOSTAT
Name shown in ETHERMA eControl App
WEEK PROGRAM ECO TEMPERATURE
During every week program eco slot the temperature is adjusted to this
value.
ECO BUTTON AND EXTERNAL PILOT SIGNAL ECO TEMPERATURE
During every eco button active time and external pilot signal active time
temperature is modified to this value.
FLOOR TEMPERATURE OFFSET (CALIBRATION)
If user's temperature measurement has offset to dial setpoint this set-
ting is used to calibrate. Note, floor sensor inside floor construction is
much warmer than real temperatures measured in room. Thus default is
-6 °C to have rotary dial adjustment range in realistic area of 18 °C - 24 °C.
AIR TEMPERATURE OFFSET (CALIBRATION)
If user's temperature measurement has offset to dial setpoint this set-
ting is used to calibrate.
27