REGULATION AND TRANSFORMATION OPERATIONS
10) REPLACING NOZZLES
The burners can be adapted to suited different
types of gas by fitting the nozzles that correspond to
the gas used. To do this, it is necessary to remove
the burner heads and use a straight key "B", to
unscrew the nozzle "A" (see fig. 12) and replace it
with a nozzle corresponding to the gas used.
We advise you to block the nozzle tightly.
After making these replacements, the technician
must regulate the burners as described in
paragraph 9, seal any regulation or pre-
BURNERS
No.
DENOMINATION
1
DOUBLE RING
2
RAPID
SEMIRAPID
3
REDUCED
4
SEMIRAPID
5
AUXILIARY
All manuals and user guides at all-guides.com
ARRANGEMENT OF THE BURNERS
TABLE
NORMAL
PRESSURE
GAS
mbar
G 30 - BUTANE
28 - 30
G 31 - PROPANE
37
G 20 - NATURAL
20
G 30 - BUTANE
28 - 30
G 31 - PROPANE
37
G 20 - NATURAL
20
G 30 - BUTANE
28 - 30
G 31 - PROPANE
37
G 20 - NATURAL
20
G 30 - BUTANE
28 - 30
G 31 - PROPANE
37
G 20 - NATURAL
20
G 30 - BUTANE
28 - 30
G 31 - PROPANE
37
G 20 - NATURAL
20
FIG. 12
regulation organs and apply the label
corresponding to the new gas regulation carried
out on the appliance in place of that previously
applied.
This label is contained in the spare
nozzle bag.
For the ease of the fitter, we have prepared a table
indicating the flow capacities, the heat capacities of
the burners, the diameter of the nozzles and the
working pressure for the various types of gas.
NORMAL
INJECTOR
RATE
DIAMETER
g/h
l/h
1/100 mm
298
2 x 69A + 46B
293
2 x 69A + 46B
390
2 x 110A + 71A
204
83
200
83
267
117 Y
98
58
96
58
133
85 Y
127
65
125
65
167
98 Z
73
50
71
50
95
75 X
16
HEAT
CAPACITY (W)
MIN.
MAX.
1800
4100
1800
4100
1800
4100
800
2800
800
2800
800
2800
650
1350
650
1350
600
1400
650
1750
650
1750
600
1750
550
1000
550
1000
450
1000