Télécharger Imprimer la page

Teka CGW LUX 60 TC 4G AI AL CI Mode D'emploi page 15

Masquer les pouces Voir aussi pour CGW LUX 60 TC 4G AI AL CI:

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
REGULATION AND TRANSFORMATION OPERATIONS
The regulation operations listed below are reserved to qualified fitters only.
After carrying out any regulation or pre-regulation operations, any seals must be replaced by the
technician.
The regulation of primary air to our burners is not necessary.
9) PROCEDURE FOR REGULATING THE MINIMUM CAPACITY OF THE BURNERS
The procedure for acquiring the minimum capacities allows the modification of the minimum capacity
programmed, adapting every burner to the characteristics of the gas distribution network to which the hob is
connected.
After switching on the hob, activate the procedure pressing the + and - buttons of burner 3 together with the
+ and - buttons of burner 1 (in model 5F) and + and - of burner 5 (in model 4F) continuously for 3 seconds,
with all the burners switched off (standby).
The activation of the regulation procedure is indicated on the display with the word "MIN". At this point it is
possible to select the burner to be regulated using buttons 12 and 13 (- and + of the clock programming),
after confirmation with the Clock button (11), the burner selected ignites at the minimum and the capacity
can be increased or decreased to the minimum level using the + and - buttons of the burner. During the
display regulation procedure, the flame display levels will show the indication - if the minimum level
programmed corresponds with the factory setting, and the indication will change
or
in flashing mode,
indicating a higher or lower capacity than that programmed.
To confirm the minimum capacity required, it is necessary to press the Clock button (11). The word "MIN" will
continue to be present and none of the leds will flash. At this point it is possible to press the Clock button
(11) to exit the procedure, or press buttons 12 and 13 to select another burner and programme its minimum
capacity. The minimum capacity levels will then be acquired and memorised by the device, and will be used
in the normal use of the hob (see fig. 11).
Selecting the type of gas
It is possible to configure the hob to work with methane gas of lpg. To activate the gas selection procedure,
the hob must be working and all the burners must be switched off. Simply press the - buttons of burner 5
and burner 1 together with button 12 (for 90 cm), - buttons of burner 5 and burner 2 together with button 12
(for 60 cm) for at least 2 seconds. The start of the gas selection procedure is indicated by the switch-off of
the burner level displays and the appearance of "Met" or "Lpg" on the timer display, depending on the
current configuration. It is possible to select the setting required, using buttons 12 and 13. To complete the
procedure the operator must press the Clock button (11).
The activation of this function implicates the cancellation of any switch-off times programmed for the burners
(see fig. 11).
THE BURNERS DO NOT REQUIRE ANY REGULATION OF THE PRIMARY AIR.
FIG. 11
15

Publicité

loading

Ce manuel est également adapté pour:

Cgw lux 90 tc 5g ai al dr ci