10. Possible causes of failure
Problem
The compressor
does not start.
The compressor
starts but there is no
pressure.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
For EU countries only
Never place any electric power tools in your household refuse.
To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and
its implementation in national laws, old electric power tools have to be separated from other waste and
disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment
must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment.
The old equipment can be returned to a suitable collection point that will dispose of the equipment in
accordance with the national recycling and waste disposal regulations. This does not apply to any ac-
cessories or aids without electrical components supplied with the old equipment.
Please note that batteries and lamps (e.g. light bulbs) must be removed from the tool before it is dispo-
sed of.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers ac-
companying products is permitted only with the express consent of the Einhell Germany AG.
Anl_TC_AC_190_24_8_SPK13.indb 18
Anl_TC_AC_190_24_8_SPK13.indb 18
GB
Cause
1. No supply voltage.
2. Insuffi cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drain plug for condensation
water (11) leaks.
1. The hose connections have a
leak.
2. A quick-lock coupling has a
leak.
3. Insuffi cient pressure set on the
pressure regulator.
- 18 -
Solution
1. Check the supply voltage, the power
plug and the socket-outlet.
2. Make sure that the extension cable is
not too long. Use an extension cable
with large enough wires.
3. Never operate with an outside tempe-
rature of below +5° C.
4. Allow the motor to cool down. If neces-
sary, remedy the cause of the overhea-
ting.
1. Have a service center replace the non-
return valve.
2. Check the seals and have any dama-
ged seals replaced by a service center.
3. Tighten the screw by hand. Check the
seal on the screw and replace if neces-
sary.
1. Check the compressed air hose and
tools and replace if necessary.
2. Check the quick-lock coupling and re-
place if necessary.
3. Increase the set pressure with the
pressure regulator.
28.06.2023 14:50:35
28.06.2023 14:50:35