Changing The Master Code - CDVI KCIEN Manuel D'installation

Clavier codé rétro-éclairé avec électronique intégrée
Masquer les pouces Voir aussi pour KCIEN:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
KCIEN - KCIENSBP
Illuminated Weatherproof Keypad - Self Contained
Example:
You have a 5-digit master code and 5-digit user
codes. You want to use 4-digit user codes.
When the number of digits in the master code
has effectively changed from 5 to 4, the user
codes become 4-digit codes at the same time.
E.g.: If your master code and user code is 1 2 3 6 9,
after the operation it will become 2 3 6 9.
If you want to switch from a master code (to one
of 5 digits follow the same procedure.
When changing from 4 to 5 digits, the figure "O"
will be added by default in front of the master
code and hence in front of the user codes.
Ex : The change from the master code 2 3 6 9
with 4 digits to one with 5 digits becomes 0 2 3 6 9.
We advise programming the codes
as 6 digits and then modifying
the code length.
C. CHANGING THE MASTER CODE
The master code is used only to enter
in programming mode.
1. Enter the master code twice.
- For the first use the factory
master code is : 1 2 3 4 5.
- Two beeps sound are emitted to confirm
entry into the programming mode.
2. Press A5 to modify the master code.
- A short beep sounds is emitted.
- Enter the 4, 5 or 6 digits
of the new master code.
- A long beep sounds is emitted to confirm
that the master code is programmed.
3. Press B to exit from the programming mode.
Two beeps sound are emitted to confirm
the return to the normal mode of operation.
D. Adding, changing or deleting
a user code
Relay 1
Group 1 : From digit place 00 to digit place 59,
Relay 2
Group 2 : From digit place 60 to digit place 99.
1. Enter the master code twice.
- For the first use the factory master code
is : 1 2 3 4 5.
8
cdvigroup.com
- Two beeps sound are emitted to confirm
entry into the programming mode.
- Enter the master code twice:
Master code
2. Enter the user location
to be programmed (from 00 to 99).
- If the digit place is free, a short beep
sounds, enter the 4, 5 or 6 digits of the code.
- If the digit place is occupied, 4 beeps sound.
- Enter the 4, 5 or 6 digits of the code
or enter 0 0 0 0 0 0 or 0 0 0 0 0 or 0 0 0 0
to cancel the existing code.
- If the Pin code is already programmed
or is identical to the master code,
then 4 beeps are emitted.
- Codes 0 0 0 0 0 0 or 0 0 0 0 0
or 0 0 0 0 serve to cancel an existing
code and hence cannot be used
as an usual code.
3. Press B to exit from the programming mode.
- Two beeps sound are emitted to confirm
the return to the normal mode of operation.
E. Time outputs
1. Enter the master code twice.
- For the first use, the factory
master code is: 1 2 3 4 5.
- Two beeps sound are emitted to confirm
entry into the programming mode.
2. Enter A0 for the key-in keypad time.
- One short beep sound is emitted.
- Enter the duration time in seconds.
E.g. : From 10 for 10 seconds to 99
for 99 seconds or enter 00 for a permanent
illumination. A long beep sounds to confirm
the programming.
3. Press A1 for output time of relay 1
- A short beep sounds is emitted.
- Enter the duration in seconds.
E.g.: 01 for 1 second up to 99 for 99 sec.
Enter 00 for a toggled output. One beep
is emitted to validate the time.
4. Press A2 for the output time of relay 2.
- A short beep sounds is emitted.
- Enter the time in seconds.
EN
Master code
2 beeps

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kciensbp

Table des Matières