CDVI KCIEN Manuel D'installation page 10

Clavier codé rétro-éclairé avec électronique intégrée
Masquer les pouces Voir aussi pour KCIEN:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
KCIEN - KCIENSBP
Illuminated Weatherproof Keypad - Self Contained
E.g.: 01 for 1 second up to 99 for 99 seconds.
Enter 00 for a toggled output. One beep
is emitted to validate the time.
5. To exit from the programming mode,
press B.
Two beeps sound to confirm the return
to the normal mode of operation.
4 beeps signal an input error.
F. Resetting the master code
- In normal operation, place a jumper at ST3.
- Wait for a beep to sound.
- Remove the jumper.
- The master code is again 1 2 3 4 5 6
in 6 digits, 1 2 3 4 5 in 5 digits or 1 2 3 4
in 4 digits.
G. Changing the code by the user
To authorize a user to modify its own User
code connect together the light green
and the purple wires
1. Enter the old user code.
The relay is activated and a beep
is emitted.
2. Enter the 2-digit sub master code
(default sub master code A and B).
A beep is emitted to authorise
the modification.
3. Enter the new user code.
2 beeps are emitted to confirm
the new code.
4. Check the new user code to be sure
of the modification.
H. Setting a sub master code
1. Enter the master code twice.
- For the first use the factory
master code is : 1 2 3 4 5.
- Two beeps sound are emitted to confirm
entry into the programming mode.
2. Press A7 to input modification digits
for group 1 user codes.
- A short beep sounds is emitted.
- Enter the two digits of the modifications.
- A long beep sounds are emitted
to confirm the programming.
3. Press A8 to input modification digits
for group 2 user codes.
- A short beep sounds is emitted.
- Enter the two digits of the modifications.
- A long beep sounds to confirm
programming.
4. Press B to exit from the programming mode.
Two beeps sound are emitted to confirm
the return to the normal mode of operation.
I. Programming the audible signal
- The audible signal is always audible
during programming.
- It is also audible on a command to open,
following the recognition of a code.
- By default, when the opening code
is entered, no "key" beep is audible.
- It is possible to authorise key beeps
by proceeding as follows:
1. Enter the master code twice.
- For the first use the factory
master code is : 1 2 3 4 5.
- Two beeps sound are emitted to confirm
entry into the programming mode.
2. Press AA.
- One beep is emitted.
- Press 0 to disable the audible signal
during a keypress.
- Press 1 to enable the audible signal
during a keypress.
- A beep is emitted to confirm the new
setting.
3. Press B to exit from the programming mode.
Two beeps sound are emitted to confirm
the return to the normal operating mode.