INSTALLATION MANUAL
KCIEN - KCIENSBP
Illuminated Weatherproof Keypad - Self Contained
6] WIRING DIAGRAM
KCIEN
KCIENSBP
Front side
ST3
Resetting
memory
KCIEN
KCIENSBP
Back side
This product is supplied with a varistor.
It should be mounted on the terminal of electric release (electromagnetic lock, solenoid bolt, etc ...) controlled
by the device.If this device controls more than one electronic release, then each lock should be fitted
with a varistor. The varistor controls the overload produced by the strike coil - back emf. It is recommended
to use a separate power supply when using a Shear Lock Magnet.
6
cdvigroup.com
Black
Red
Dark green
H2
Purple
Pink
Light blue
H1
Light green
Blue red
Pink Grey
Magnetic lock
Green white
Brown
Orange
Strike
Yellow
White
Electric strike
Grey
Varistor
Outputs
Black
Red
Pink
Purple
Dark green
Green White
Blue red
Pink gray
Orange
Yellow
Brown
Light blue
Light green
White
Grey
Power supply
12V to 24V ac
or 12V to 48V dc
Power control side
power supply
Description
Input voltage 12V to 24V ac or 12V to 48V dc
Input voltage 12V to 24V ac or 12V to 48V dc
Relay 1 request to exit input
Common
Clock switch (H1)
Relay 2 N/C contact
Relay 2 common
Relay 2 N/O contact
Relay 1 N/C contact
Relay 1 common
Relay 1 N/O contact
Request-to- enter input
User code change
Tamper switch output
Tamper switch output
EN