c. Choosing the Correct Temperature Series
Each cartridge is specially designed for high power delivery, which means that you
can often solder with a Metcal cartridge at a temperature 100°F (40°C) or more
lower than with a conventional soldering iron. Since Metcal tip cartridges sense
thermal loads and respond to them, you need only approximate the size of the
loads you will be working with. Start with a lower temperature, going to a higher
temperature only when necessary.
CARTRIDGE CONSTRUCTION AND IDENTIFICATION
Coil Assembly
Shaft
Magnetic Shield
Heater
d. Temperature Series Chart
Application
X=Series
500
High Thermal
Sensitivity
Series
Moderate
600
Thermal
Series
Sensitivity
700
Moderate
Thermal Mass
Series
800
High Thermal
Mass
Series
Note: Not all temperature series available for some styles. Please consult Metcal's
webpage (www.metcal.com) or catalog for a complete listing.