7. Connecting the cables
Power supply
OSYnet-SafetyController 2
OSYnet-SafetyController 2 SE
Output for signalling
the opera on mode
Connection terminals: Pluggable screw terminals, stripping length: 7 mm. Power supply
connection: 1 wire per terminal; Other connections: 2 wires per terminal.
Power supply for 76 2200 00
(hospital etc.)
Cable: NYM 2x2.5 mm²
max. 1 wire per connec on point
Power supply for 78 2200 00
(prison etc.)
Cable: NYM 3x2.5 mm²
max. 1 Ader per connec on point
The earth conductor (yellow-green)
*)
must be connected through using
a splicing connector.
00 8804 70, 09/23 (Rev. 1.0)
OSYnet group bus
Order No. 76 2200 00
Order No. 78 2200 00
Input
Made in Germany
Output for
signalling of faults
from previous
*)
Splicing connector
e.g. Wago 221-412