5.
The height of the canopy can be adjusted by rotating the
two screws (R) indicated in FIGURE 9. These are also used
to insure that the canopy is level. Once the desired height
is achieved and the canopy is level, insert the permanent
attachment screw (U). This screw insures that the canopy
cannot be dislodged from the mounting bracket.
R
FIGURE 9
6.
Connect the Power Supply Cable to the rangehood.
Attach the White lead of the power supply to the White lead
of the rangehood with a twist-on type wire connector. Attach
the Black lead of the power supply to the Black lead of the
rangehood with a twist-on type wire connector. Connect the
Green ( Green and Yellow ) ground wire under the Green
grounding screw.
7.
If your installation uses a remote blower, connect the
wiring cable for the remote blower. DO NOT connect the remote
blower to the Power Supply Cable. The wiring diagram for this
rangehood is supplied next to the Use and Care Information
on the rear of the Installation Instructions.
8.
Replace the field wiring compartment cover and the
grease filters.
For ductless installations:
Ductless installations with the chimney require a ductless kit.
This kit consists of a lower chimney cover with holes for the
exhaust air, a ductless diverter, two grids to cover the holes in
the chimney cover, two charcoal filters. The ductless diverter
must be installed before the lower chimney cover is attached
as in FIGURE 10.
FIGURE 10
The lower chimney cover without holes should be discarded.
Once the lower chimney cover with holes is installed, the grids
are inserted into the holes as illustrated in FIGURE 11.
FIGURE 11
For ductless installations without the chimney, a ductless grate
must be attached to the opening on the top of the canopy as
indicated in FIGURE 12.
R
V
R
FIGURE 12
9.
For ducted installations, the damper must be attached
to the exhaust opening on the top of the canopy. Two small
phillips screws are provided with the damper to attach it to
the canopy. Connect the ductwork and seal all connections
with duct tape.
10. For ducted installations and ductless installations with
the chimney, the chimney must be attached to the body of
the rangehood. The upper section of the chimney (S) must
be installed first, then the lower section (I). Both sections are
secured to the wall under the mounting brackets as indicated in
FIGURE 13. Once the chimney is in the final position, screws
are used to secure the top and bottom of the chimney to the
brackets.
2
3
1
FIGURE 13
11. Turn the power supply on. Turn on blower and light.
The rangehood controls are located in a gray panel on the
canopy's underside. To open the panel, press up on the
front edge and release as indicated in FIGURE 14. If the
rangehood does not operate, check that the circuit breaker
is not tripped or the house fuse blown. If the unit still does
not operate, disconnect the power supply and check that the
wiring connections have been made properly.
FIGURE 14
G
S
I
Version 11/00 - Page 6