TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• Wiring Cable - Optional Remote Blower Only
• 1 Wall or Roof Cap
• All Metal Ductwork
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless.
The blower can be vented through the wall or ceiling. To
vent through a wall, a 90° elbow is used. When installed
ductless,this rangehood can be used with or without the
chimney. Ductless installations with the chimney require a
Ductless Kit, available from your dealer. Ductless installations
without the chimney use the ductless grate included with the
rangehood (G in Figure 1).
This rangehood can be used with an optional remote blower.
If a remote blower is used, then the internal blower must be
removed and discarded. Both blowers cannot be used together.
The remote blower connects to the rangehood using a separate
wiring cable not supplied with the rangehood. The wiring cable
should be installed at the same time as the ductwork.
WARNING! BEFORE MAKING ANY CUTS OR HOLES
FOR INSTALLATION, DETERMINE WHICH VENTING
METHOD WILL BE USED AND CAREFULLY CALCULATE
ALL MEASUREMENTS.
RANGEHOOD ASSEMBLY
4
S
3
2
I
B
-
OPTIONAL BACKSPLASH
C
-
CANOPY
G
-
DUCTLESS GRATE
S
-
UPPER CHIMNEY
I
-
LOWER CHIMNEY
1
-
RANGEHOOD MOUNT BRACKET
2
-
LOWER CHIMNEY BRACKET
MIDDLE CHIMNEY BRACKET
3
-
4
-
UPPER CHIMNEY BRACKET
FIGURE 1
The Egyzia chimney is adjustable and designed to meet
varying ceiling heights. FIGURE 2 illustrates the standard
installation for the Egyzia which requires the canopy to be
mounted 24" above the countertop. The chimney can be
adjusted for ceilings between 8 feet and 9 feet.
Min. - 4 1/2"
Max. - 20"
22"
9 1/2"
24"
36"
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 35 feet if ducted with the
required minimum of 3 1/4" by 10" rectangular duct and 60
equivalent feet if ducted with 9" round ductwork. Calculate
the length of the ductwork by adding the equivalent feet in
FIGURE 3 for each piece of duct in the system An example
is given in FIGURE 4. For best results, use no more than
three 90° elbows. Make sure that there is a minimum of 24"
of straight duct between elbows if more than one is used.
Do not install two elbows together. Remote blowers require
9" round duct.
45˚ Elbow
90˚ Elbow
1
90˚ Flat Elbow
G
Wall Cap
C
FIGURE 3
B
!
Because of the weight and size of the rangehood
canopy, two or more people are needed to move
and safely install the rangehood canopy.
Failure to properly lift rangehood could result in
damage to the product or personal injury.
INSTALLATION DIMENSIONS
upper
chimney
cover
lower
chimney
cover
canopy
14 3/16"
Min. 96"
Max. 111 1/2"
FIGURE 2
3.0 feet
9 Feet Straight Duct
5.0 feet
2 - 90˚ Elbows
12.0 feet
Wall Cap
0.0 feet
Total System
FIGURE 4
WARNING
PERSONAL INJURY HAZARD
Version 11/00 - Page 4
9.0 feet
10.0 feet
0.0 feet
19.0 feet