Télécharger Imprimer la page

Balluff BTL7-V50E-M P-C003 Serie Notice D'utilisation page 30

Système de mesure de position magnétostrictif, ethercat

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
BTL7-V50E-M _ _ _ _ -P-C003
Magnetostrictive Linear Position Sensor – Profile Style
3
Construction and function (continued)
3.3
LED display
LED 4
(Link/Activity
OUT)
LED 1
(BTL status)
Fig. 3-2:
BTL7 LED displays
3.3.2
LED 2: EtherCAT status
LED 2
Green
Off
Flashing (2.5 Hz)
Single flash
(1 flash/s)
On
Flickering (10 Hz)
Red
On
Double flash
Single flash
Flashing
Flickering
Off
Tab. 3-2:
LED 2
3.3.3
LED 3 / LED 4: Link/Activity
LED 3/LED 4
Status
Green
On
Port open
Flickering
Port open
Off
Port closed
Inverted double
Port closed (must be
flash
opened manually)
Tab. 3-3:
LED 3/4
8
english
LED 3
(Link/Activity
IN)
LED 2
(EtherCAT
status)
Slave status
Error
INIT
PRE-OP
SAFE-OP
OP
INIT
Application error
Timeout of process data
watchdog/timeout of EtherCAT
watchdog
Local error
Invalid configuration
Error during boot-up
No error
Connection
Yes
Yes
Data is being
exchanged
No
Yes
3.3.1
LED 1: BTL status
LED 1
Operating state
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
Tab. 3-1:
LED 1
Meaning
The device is in the INITIALISATION state
The device is in the PRE-OPERATIONAL state
The device is in the SAFE-OPERATIONAL state
The device is OPERATIONAL
The device is starting and has not yet reached
the INIT state.
A critical application or communication error has
occurred.
The application has exceeded the time limits.
The device has automatically changed the
EtherCat status because of a local error. The
error indicator in the AL status register is set to 1.
General configuration error
An error was detected during the start-up
process. The INIT state has been reached, but
the error indicator in the AL status register is set
to 1.
EtherCAT communication functions without any
errors.

Publicité

loading