Maintenance and Troubleshooting
Inspect Engine Spark
WARNING
Accidental Start-up. Disconnect spark plug wire
when working on unit. Failure to do so could result
in death or serious injury.
1. Disconnect spark plug wire from spark
plug.
2. Secure spark plug wire where it cannot
contact spark plug.
3. Test spark plug with approved spark plug
tester.
NOTE: DO NOT inspect for spark with spark
plug removed.
Inspect Muffler And Spark Arrestor
NOTE: It is a violation of California Public
Resource Code, Section 4442, to use or
operate the engine on any forest-covered,
brush-covered, or grass-covered land unless
the exhaust system is equipped with a spark
arrestor, as defined in Section 4442, maintained
in effective working order. Other states or
federal jurisdictions may have similar laws.
NOTE: Call 1-888-GENERAC (1-888-436-
3722)
with
questions
replacement.
NOTE:
Use
ONLY
replacement parts.
Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrestor, if equipped,
inspect for damage or carbon blockage. If
replacement parts are required.
Inspect Spark Arrestor Screen
(if equipped)
WARNING
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
1. See
Figure 4-9
fasteners and remove spark muffler cage
(A) and heat shield (B).
2. See
Figure
4-11. Loosen fasteners (C) and
remove spark arrestor from muffler.
3. Inspect spark arrestor. Replace if torn,
perforated or otherwise damaged.
4. If screen is not damaged, clean it with a
commercial solvent and replace.
16
(000102)
about
component
original
equipment
(000108)
and
Figure
4-10. Loosen
A
A
Figure 4-9. Spark Arrestor Fasteners
B
Figure 4-10. Heat Shield Fasteners
C
Figure 4-11. Spark Arrestor Fasteners
Owner's Manual for Power Washer