signal is activated and the timer display
shows the flashing "00" symbol. The
LED of the corresponding timer flashes
at the same time. The cooking area
programmed turns off and the symbol
GB
"0" is displayed fixed. The symbol "H" is
displayed after 10 seconds (deselection
time) in correspondence with a hot hob
zone ("hot"). Otherwise the symbol "0" is
displayed.
– The acoustic signal and flashing hob
zone LED stop after 2 minutes and/or
activating any key.
At this point the displays disappear and the
hob zone remains deselected.
The behaviour of the specific hob zone timer
is similar to that of the independent timer.
If a timer is programmed for a hob zone, the
limitation of the operating time depend on
the timer value and not on the value of the
standard table.
The precision of the timer value depends
on the precision of the clock μC that can
deviate by +/- 4% in 99 minutes.
Food warmer function (optional)
The food warmer function keeps the food on
a hob zone warm.
In this case the selected hob zone is
activated at low power.
When the food warmer function is activated
for a hob zone, the corresponding display
indicates the "u" symbol (see symbols).
Activation/Deactivation
The food warming function can also be
activated as an additional cooking level
between 0 and 1.
To use the foodwarmer function, select an
area, set it to 1 using the slider and then
immediately to 0. For the operating times,
see the table.
All manuals and user guides at all-guides.com
Time limitation of the heat holding
function
For microbiological reasons, the food
warming function should not be used for
excessively prolonged periods (maximum
1 hour. For this reason the Touch Control
automatically switches off after 2 hours).
PAUSE
Activation of the pause function
When at least one hob zone is functioning,
the heating elements can be deactivated by
pressing the Pause key.
The pause display has priority.
The
timers
that
programmed (also for the independent
timer) are stopped and do not function
during the pause time. The automatic heater
and booster are also deactivated on all the
hob zones during the activation, while the
calculation of the residual heat and the
limitation of the operating time continues to
function without being stopped.
The LEDs of the other functions (timer)
remain on depending on their status.
The pause can last up to 10 minutes. If it is
not terminated within this time interval, the
command is deactivated. The hob zone can
be switched at any time by means of the
On/Off key. Any active pause functions are
in this way terminated.
Termination of the Pause function
To terminate the Pause mode and start the
operation again, the Pause key and any
other key (not the same key again) must be
activated within 10 seconds.
In this way the function existing before the
Pause is re-established. If no other key is
activated within the 10 seconds, the hob
zone is also switched off.
40