4.5.1 Calling up and setting operating modes
To call up one of the operating modes:
▶ Press the
key repeatedly until the indicator light below
the pictogram of the required operating mode lights up.
The last temperature set in this operating mode appears on
the display.
To change the temperature of the operating mode:
▶ Press the
or
key until the required temperature is
set.
The set temperature is saved automatically if the key is not
pressed for 5 seconds.
The room temperature appears on the display.
4.5.2 Heating mode operation mode
The control unit keeps the convector at the set temperature.
The temperature can be set from 7 °C and 12 °C up to 28 °C.
The default setting is 19 °C.
To call up and set the heating mode operating mode:
▶ Proceed as described in Chapter 4.5.1, page 57.
If the temperature for the heating mode operating mode is
lower than the ECO operating mode temperature, the
temperature setting for the ECO operating mode is
automatically reduced to 1 °C below the temperature of the
heating mode operating mode.
Predefined day programs P1 up to P5
The heating phases of the predefined programs are shown in
the following tables.
The programs (P1...P5) cannot be changed.
Duration
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Operation
mode
Table 56 Program P1
P1 is the recommended predefined program for daytime
absence (operating mode ECO:22:00...06:00 Clock and
Duration
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Operation
mode
Heat Convector 4000 – 6720883017 (2022/12)
4.5.3 Operating mode ECO
The temperature default setting for the ECO operating mode is
3 °C below the temperature of the heating mode operating
mode.
The temperature can be set from 6 °C to 1 °C below the
temperature of the current operating mode.
To call up and set the ECO operating mode:
▶ Proceed as described in Chapter 4.5.1, page 57.
We recommend setting the ECO operating mode during the
night or if the room is not going to be used for more than 2
hours.
4.5.4 PROG operating mode
To call up and set the PROG operating mode:
▶ Proceed as described in Chapter 4.5.1, page 57.
The temperatures set under 4.5.2 and 4.5.3 apply for the
PROG operating mode. The day and week program controls
which operating mode is active and when.
There are 5 predefined day programs (P1...P5). One other day
program (P6) can be adjusted individually ( Chapter 4.5.5,
page 58). The week program (7d) is comprised of these
programs. The week program can be adjusted individually
( Chapter 4.5.6, page 59).
In the following tables, a black square represents the heating
mode operation mode and an empty cell represents the ECO
operating mode.
08:00...18:00 Clock; heating mode operating mode:
06:00...08:00 Clock and 18:00...22:00 o'clock).
Operation