Fuse change (TEB-3 – 12 V only)
Please pay attention to the ESD regulations!
The device fuse (F1) is on the electronic control unit in the
device.
– Switch fan so that it is voltage-free (disconnect battery, dis-
connect mains plug if necessary).
– Remove connectors from power supply and control panel.
– Remove 2 screws (1) from the housing – take off housing.
– Hold the edges of the PCB and pull it out of the housing.
– Always replace defective fuses with identical fuses (see
"Technical data").
– Insert PCB into the housing.
– Secure housing to fan with 2 screws (1) after changing the
fuse.
– Attach connectors of control panel and power supply (ob-
serve correct polarity, otherwise the control panel will not
function and the fan will run in the wrong direction).
– Reconnect battery, re-establish mains connection if
necessary.
10
1
F1
TN-3 – 230 V
External control panel
b
a

230 V ~

a = Control knob for fan power (1 – 5)
b = Rotary switch for operating modes
c = Off
d = On, manual fan power setting
Set required speed at control knob (a).

Disposal

The device must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-life Vehicle Regulation) must be observed.