4.9 Reset mode (time meter)
4.10 End of programming
All manuals and user guides at all-guides.com
manual reset (red key)
and electrical reset
no reset
(red key and reset input
locked)
electrical reset only
manual reset only
Programming routine will
be passed through once
again. All parameters can
be checked.
Programming routine will
be left and the new
parameters will be stored.
Afterwards the device is
ready to use.
5. Terminal assignment
1
10-30 VDC
2
0 V (GND)
3
INP A
4
INP B
5
RESET
6. Technical data
Supply voltage:
10...30 VDC, max. 50 mA
Display:
6digit LED-Display, 8 mm character height
Polarity of input signals:
programmable for inputs in common (npn or pnp)
Input resitance: appr. 10 k
Count frequency:
20 kHz can be damped to30 Hz
Min. pulse length of the reset input: 5 ms
Input sensitivity:
log. „0": 0 VDC..0,2xU
log. „1": 0,6 x U
Pulse shape: variable (Schmitt Trigger
characteristic)
Data retention:
6
via EEPROM 1x10
memory cycles or 10 years
Accuracy:
hour meter/ time meter mode: < 50 ppm
Noise immunity:
EN 50081-2; EN 55011 class B; EN 50082-2
Ambient temperature: -10 °C...+50 °C
Storage temperature: -25 °C...+70 °C
Weight: appr. 50 g
Protection: IP 65 (front)
Cleaning:
The front of the unit is only to be cleaned with a
soft wet (water !) cloth.
7. Delivery includes:
- CODIX 527
- Panel mounting clip
- Bezel for screw mount, panel cut-out 50x25 mm
- Bezel for clip mount, panel cut-out 50x25 mm
- Sealing
8. Ordering code:
6.527.012.300
W
B
..30 VDC
B
7