Operating instructions
Electronic totaliser and time meter
CODIX 527
1. Description
• 6digit totaliser and time meter, resetable
• LED-Display with 8 mm high characters and
very high luminosity
• Display range 0..999999 with leading zero
blanking.
• Programming of count functions and operating
parameters via the setting keys. During
programming the display guides the user with
text prompts.
• Programmable features:
Input polarity (npn or pnp)
Max. count frequency (30 Hz or 20 kHz)
Scaling factor
Decimal point (totaliser)
Reset mode ( totaliser):
electrical
manual
manual and electrical
no reset
Input mode (time meter)
Decimal point (time meter)
Reset mode (time meter):
electrical
manual
manual and electrical
no reset
2. Inputs
INP A
Dynamic count input for the totaliser.
INP B
Start/Stop or gate input for the time meter
(depending on chosen input mode)
RESET
Dynamic reset input. Linked to the red reset key.
Can be programmed for each counter separately.
3. Setting of the parameters
3.1 Selecting the displayed value
By pressing the right key, it can be chosen
whether the current value of the adding counter or
the time meter is displayed.
Pressing the right key once the current function
(„total" or „time") is displayed for 2 seconds. If
within this period the right key is pressed again,
the current function is changed. The display
shows the new function „time" or „total".
All manuals and user guides at all-guides.com
3. 2 Setting the operating parameters
a. Hold down both keys on front panel and switch
b. The display shows
c. After releasing the keys the display alternates
d. Pressing the right key, the menu item will be
e. Hold down the left key and press the right key
f. After programming the last menu item, the
4. Programming routine
Programmable parameters are shown in
succession. After one pass, the device is fully
programmed.
In each case the first shown item is the factory
preset.
4.1 Input polarity
4.2 Activating the 30 Hz filter
on the supply voltage.
between menu title and corresponding menu
item at a frequency of 0.5 Hz. After any key is
pressed, only the menu item is displayed.
switched to next value.
to switch to the next menu title.
programming routine will be left and the new
values will be stored by switching the menu
item to „YES". If you chose „NO", the
programming routine will be passed through
once again.
npn: switching to 0 V
pnp: switching to +24 V
Start/Stop inputs: normal
operation
Start/Stop inputs: damped,
e.g. when using
mechanical switches
5