[4]. Reconnect the connectors to the monitor.
[5]. Configure the monitor according to the
installation (see 5 - Configuring the
monitor, page 7).
[6]. Clip the front panel of the monitor to
the rest of the unit.
[7]. Switch the mains power supply back
on.
[8]. Test the installation.
Cable section
Cable
CAT5 UTP/CW1308
Telephone cable
2 wires

4.2 Local buzzer

It is possible to connect a buzzer button to the GNDA and LB terminals of the monitor. When this push button is activated, the
monitor rings (different sound from that caused by a call from the external module), but the screen remains in standby mode.
This push button does not need to be connected to any voltage source (dry contact only).

4.3 Additional modules

Depending on the type of installation, you may use the following modules:
1841218
External "Origin" 1-button module
1841219
External "Premium" 1-button module
1841221
External "Premium" 2-button module
1841220
External code keypad module
9020027
230V power supply
9020028
230V power supply for multi-peripherals
9020029
Passive distributor
9020030
Input exchanger
9020031
Two-relay module
9020032
Transformer for code keypad
To connect these different modules, please consult the specific instructions.
6
Maximum distance between
Section
the external module and the
(mm²)
most distant monitor (m)
0.50
0.22
0.28
0.5
Maximum distance between the power
supply and the most distant monitor (m)
250
100
150
70
External module with one call button
External module with one call button and a badge
reader
External module with two call buttons and a badge
reader
Code keypad to complement the functions of an
external module
Standard power supply for an installation with
an external module and video display on a single
monitor
Enhanced power supply for an installation with
several external modules and simultaneous
display on two monitors
Module allowing the bus line to be distributed
between two houses
Module enabling up to four external modules to be
connected to an installation
Module enabling different configurations, for
example:
Control of an electric lock and a motorised gate
with full opening and "pedestrian" opening.
Control of an audible alarm and a visual alarm.
Specific transformer allowing the code keypad to
be connected to the bus line
Copyright © 2016 Somfy SAS. All rights reserved.
Clic !
100
50
50
30