15-5/8"
(397 mm)
20-1/8"
(511 mm)
2" NPT
Tap
17-1/2" (445 mm)
Standard Installation
10-1/8" (257 mm)
ADA Installation
Roughing-In
• Roughing-in dimensions are identical if using an optional 3"
outlet spud.
• The urinal complies with ADA requirements when the rim is
mounted no higher than 17" (432 mm) from the finished floor.
1. Prepare the Site
NOTE: If an existing waste pipe will be used and will result in an
acceptable rim height (refer to the rough-in dimensions), follow the
retrofit installation instructions.
For Retrofit Installations
Turn the water supply OFF, remove the existing urinal, then cap
the water supply line inside the wall.
For New Installations
Install a waste pipe as necessary to conform to the roughing-in
dimensions.
Install adequate support framing for the wall hangers.
Kohler Co.
Wall Hangers
16-1/8"
Internal
(410 mm) to
Lip
Center of
Hanger Slots
24" (610 mm)
Standard Installation
17" (432 mm)
ADA Installation
2" NPT Tap
1/4"
(6 mm)
Spud Detail
3
6-3/4"
(171 mm)
29-5/8"
(752 mm)
15" (381 mm)
6"
(152 mm)
1048745-2-G