Inspect the inside of the unit for damage. Ensure that
blower assembly, heat or energy recovery core, core
fi lters, insulation, dampers, etc. are all intact, then
reinstall the door.
2.2 I
K
, T
NSTALLATION
ITS
OOLS AND
The installation kit needed to perform most installations is IKSV1000 for Venmar units. Following are the tools and
material needed:
•
Measuring tape
•
Phillips no. 2 or Robertson no. 2 screwdriver
•
Small fl at blade screwdriver (for wall control connection)
•
Wire stripper (for wall control connection)
•
Hammer and fl at blade screwdriver (for plenum connection installation only, to make holes in existing metal duct)
•
Scissors or utility knife (to cut duct tape)
•
Duct tape
•
Tin snips or metal shear (for plenum connection installation only, to cut ductwork)
•
Aluminum duct tape (for plenum connection installation only)
•
Jig saw
•
Caulking gun and caulking
2.3 L
M
OCATING AND
OUNTING THE
Choose an appropriate location for the unit:
• Within an area of the house where the ambient temperature is kept between 10°C (50°F) and 40°C (104°F);
• Away from living areas (dining room, living room, bedroom), if possible;
• So as to provide easy access to the interior cabinet for maintenance, and to the control panel on the side of the unit;
• Close to an exterior wall, so as to limit the length of the insulated fl exible ducts to and from the unit;
• HRV units only: close to a drain. If no drain is close by, use a pail to collect run-off;
• Away from hot chimneys, electrical panel and other fi re hazards;
• Within 6 feet of a power source (standard outlet).