Follow these steps to ensure a successful boot:
•
Seal all the ductwork with tape. Close all windows and doors.
•
Turn off all exhaust devices such as range hood, dryer and bathroom fans.
•
If the installation is in any way connected to a ductwork of a central forced-air system, make sure that the central forced-air
system blower is ON. If not, leave central forced-air system blower OFF.
B
U
P
OOT
P
ROCEDURE
•
Plug the unit and wait for the STB mode to display on the LCD screen. If unit is colder than ambient temperature, it is normal to
experience a 60 s longer boot-up since motors have to preheat.
4.3 S
M
ETTINGS
ODIFICATION
•
Go to CFG OPT using (+/-) then press on the OK button for 4 seconds.
Options
Confi gurations available
DIS* (Discretion - defrost without speed variation for more comfort),
DEF (Defrost)
PLU (Plus - extended defrost for colder areas)
STB (Standby - 20 min in MIN speed and 40 min in standby mode), REC* (Recirculation - 20 min
in MIN speed and 40 min in recirculation mode)
INT (Intermittent)
NOTE: Following ducting installation confi guration and temperature conditions, it may be
necessary for the unit to operate continuously. Refer to section 2.4 for more details.
HRV110 DFT* (Default - MIN/MED/MAX = 50/81/112 CFM)
HRV110 TDM (Tandem - MIN/MED/MAX = 50/64/90 CFM)
SPD (Speed)
ERV130 DFT* (Default - MIN/MED/MAX = 64/96/131 CFM)
ERV130 TDM (Tandem - MIN/MED/MAX = 50/70/105 CFM)
* Factory setting
NOTE: If no selection is confi rmed within 10 minutes, the unit will exit the menu without saving any changes.
4.4 F
S
R
ACTORY
ETTINGS
ESET
If needed, reset settings to restart the boot up procedure.
P
ROCEDURE TO RESET SETTINGS
Press on the OK and (-) buttons simultaneously for 4 seconds. Use (+/-) to select Yes or No and OK to confi rm.
Then perform the boot up procedure.
4.5 M
M
ANUAL
ODE
This mode is meant for qualifi ed personnel only in case of troubleshooting. Operating the unit continuously
in manual mode can reduce comfort and increase risk of frost following improper airfl ows confi guration.
Damage to the unit and/or property damage could result. It is highly recommended to use manual mode on
a temporary basis only when needed and to reset the unit factory settings once the use of this mode is over
(refer to section 4.4).
Press simultaneously (+/-) buttons for 4 seconds.
Use (+/-) to adjust fresh air airfl ow and OK to confi rm.
Use (+/-) to adjust stale air airfl ow and OK to confi rm.
If needed, press OK to readjust airfl ows.
Press + or - button, change mode on main wall control or use optional auxiliary wall control to
leave manual mode.
When leaving manual mode, settings are lost.
DEFINITION
Standby mode
MED speed
Intermittent mode
Recirculation mode
(Min, Med or Max speed)
AUTO mode
Override 20 min
DISPLAY
OVR 40
OVR 60
TUR
DEF
EXX or WXX
(XX referring to error or warning
number)
CAUTION
16
DEFINITION
Override 40 min
Override 60 min
Turbo mode
Defrost mode
Refer to section 7 for each error/warning
explanation