Recycling; Troubleshooting - Zipper Maschinen ZI-MOS125 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
19

RECYCLING

Do not dispose of your machine in residual waste. Contact your local authorities for
information on available disposal options. If you buy a new vibratory plate or
equivalent from your dealer, he is obliged in certain countries to dispose of your old
machine properly.
20

TROUBLESHOOTING

Hot surfaces and rotating machine parts while the engine is running can cause
serious injury or even death. Always stop the machine before carrying out
troubleshooting work and secure it against unintentional restarting.
Fault
Motor does not start
Motor stops
Engine does not deliver
enough power:
Bad cuts
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-MOS125
W A R N I N G
Possible cause / remedy
Check O
/O
switch and make sure it is positioned to
N
FF
"O
".
N
Check fuel supply.
Make sure that the spark plug ignition cable is
connected.
Check spark plug
Check carburettor and air filter and make sure they
are clean.
Fuel not sucked in / press pump
Check fuel supply.
Check the condition of the air filter.
Check fuel supply.
Check the condition of the air filter.
Check throttle position
Foreign material wrapped,grass around the trimmer
 Remove material