Page 2
All manuals and user guides at all-guides.com...
Page 3
All manuals and user guides at all-guides.com OUTLINE AND DIMENSIONS Indoor Unit (CC series) All dimensions are in mm MODEL CC 10CW 212,8 CC 15CW 212,8 CC 20CW 1041 1002 1065 212,8 CC 25CW 1176 1137 1097 1200 212,8 Indoor Unit (CC series)
Page 4
All manuals and user guides at all-guides.com ! Caution Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places. ! Avertissement Les bords coupants et les surfaces du refroidisseur tubulaire présentent un risque de blessure.
Page 5
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. CHILLED WATER FAN COIL UNIT CEILING CONCEALED SPLIT TYPE AIR CONDITIONER MODEL CC10CW/MCC010CW CC30CW/MCC030CW CC15CW/MCC015CW CC40CW/MCC040CW CC20CW/MCC020CW CC50CW/MCC050CW CC25CW/MCC025CW CC60CW/MCC060CW Part No.: A08019025463 IM-CCCW-1100 (1)-McQuay...
Page 6
All manuals and user guides at all-guides.com CONTENTS - Outline and Dimensions page i-ii - Safety Precautions page 2 - Installation Diagram page 3 - Installation of The Indoor Unit page 3 - Electrical Connection page 3 - Water Piping Connection page 4 - Electrical Wiring Connection page 4...
Page 7
1326 1526 L (mm) ELECTRICAL CONNECTION CC10CW - CC25CW MODEL CC 10CW CC 15CW CC 20CW CC 25CW Voltage Range 220V – 240V / 1Ph / 50Hz + ! or 208V – 230V / 1Ph / 60Hz + ! Recommended Fuse...
Page 8
All manuals and user guides at all-guides.com CC28CW - CC60CW MODEL CC 28 / 30CW CC 38 / 40 CW CC 50CW CC 60CW Voltage Range 220V – 240V / 1Ph / 50Hz + ! or 208V – 230V / 1Ph / 60Hz + ! Recommended Fuse Power Supply Cable Size Number of Conductors...
Page 9
All manuals and user guides at all-guides.com CC10CW~CC25CW (with netware-1 controller) FCU 1 FCU 2 FCU 3 COMP L COMP L COMP L Solenoid Valve for 3 way valve Chiller x1, x2, x3 Relay (220-240V, 10A) OVERALL CHECKING Ensure the following, in particular:- 1) The unit is mounted solidly and rigid in position.
Page 10
All manuals and user guides at all-guides.com TROUBLE SHOOTING When any malfunction of the air conditioner unit is noted, immediately switch off the power supply to the unit. Check the following fault conditions and causes for some simple trouble shooting tips. FAULT CAUSES 1.
Page 11
Des ajustements peuvent être nécéssaires pour suivre les réglementations locales. Avant d’installer et de faire fonctionner le climatiseur, lisez attentivement ce manuel et conservez le. VENTILO-CONVECTEUR A EAU GLACEE MODÈLE CLIMATISSEUR POUR FAUX-PLAFOND MODÉLE CC10CW/MCC010CW CC30CW/MCC030CW CC15CW/MCC015CW CC40CW/MCC040CW CC20CW/MCC020CW CC50CW/MCC050CW CC25CW/MCC025CW CC60CW/MCC060CW Part No.: A08019025463 IM-CCCW-1100 (1)-McQuay...
Page 12
All manuals and user guides at all-guides.com SOMMAIRE - Contour et Dimensions page i-ii - Précautions de Sécurité page 2 - Schéma D'installation page 3 - Installation de L’unité Intérieure page 3 - Raccordement Électrique page 3 - Schema des Connexions des Tuyauteries Pour L'eau page 4 - Schema des Connexions Électrique page 4...
Page 13
1326 1526 L (mm) RACCORDEMENT ÉLECTRIQUE CC10CW - CC25CW MODÉLE CC 10CW CC 15CW CC 20CW CC 25CW Tension d'alimentation 220V – 240V / 1Ph / 50Hz + ! ou 208V – 230V / 1Ph / 60Hz + ! Fusible aM Section du câble d'alim...
Page 14
All manuals and user guides at all-guides.com CC28CW - CC60CW MODÉLE CC 28 / 30CW CC 38 / 40 CW CC 50CW CC 60CW Tension d'alimentation 220V – 240V / 1Ph / 50Hz + ! ou 208V – 230V / 1Ph / 60Hz + ! Fusible aM Section du câble d'alim Nombre de conducteurs...
Page 15
All manuals and user guides at all-guides.com CC10CW~CC25CW (Avec unité de contrôle netware-1) FCU 1 FCU 2 FCU 3 COMP L COMP L COMP L Valve de solénoïde pour la valve de 3 voies Refroidisseur x1, x2, x3 Relais (220-240V, 10A) CONTRÔLE GÉNÉRAL Vérifier scrupuleusement les éléments suivants :- 1) L’appareil est monté...
Page 16
All manuals and user guides at all-guides.com ANALYSE DES CAUSES DE DYSFONCTIONNEMENT En cas de dysfonctionnement du climatiseur, couper aussitôt l’alimentation électrique. Vérifier ensuite les points suivants pour détecter la nature et les causes de la panne. DEFAUTS CAUSES 1. Le climatiseur ne fonctionne pas. - Le circuit est peut être coupé...
Page 17
Je nach den örtlichen Gegebenheiten können spezielle Anpassungen notwendig sein. Vor der Inbetriebnahme des Klimagerätes dieses Handbuch bitte aufmerksam zur Kenntnis nehmen und für künftigen Bedarf aufbewahren. KÜHLWASSER-VENTILATOREINHEIT UNTER DER DECKE VERLAUFENDE GETEILTE KLIMAANLAGE MODELL CC10CW/MCC010CW CC30CW/MCC030CW CC15CW/MCC015CW CC40CW/MCC040CW CC20CW/MCC020CW CC50CW/MCC050CW CC25CW/MCC025CW CC60CW/MCC060CW Part No.: A08019025463 IM-CCCW-1100 (1)-McQuay...
Page 18
All manuals and user guides at all-guides.com INHALT - Auslegung und Abmessung page i-ii - Sicherheits-Massnahmen page 2 - Installationsdiagramm page 3 - Installation des Innenmontage-Gerätes page 3 - Elektroanschluss page 3 - Wasserrohranschluss page 4 - Elektrischer Kabelanschluss page 4 - Gesamtüberprüfung page 5 - Instandhaltung &...
Page 19
1076 1326 1526 L (mm) ELEKTROANSCHLUSS CC10CW - CC25CW MODELL CC 10CW CC 15CW CC 20CW CC 25CW Spannungsbereich 220V – 240V / 1Ph / 50Hz + ! oder 208V – 230V / 1Ph / 60Hz + ! Empfohlene Sicherung...
Page 20
All manuals and user guides at all-guides.com CC28CW - CC60CW MODELL CC 28 / 30CW CC 38 / 40 CW CC 50CW CC 60CW Spannungsbereich 220V – 240V / 1Ph / 50Hz + ! oder 208V – 230V / 1Ph / 60Hz + ! Empfohlene Sicherung Zuleitungskabelquerschnitt Adernanzahl...
Page 21
All manuals and user guides at all-guides.com CC10CW~CC25CW (Mit Netzware -1 Regler) FCU 1 FCU 2 FCU 3 COMP L COMP L COMP L Elektromagnetventil für das 3-Weg Ventil Kühler x1, x2, x3 Relais (220-240V, 10A) GESAMTÜBERPRÜFUNG Achten Sie insbesondere darauf, dass:- 1) Das Gerät fest und solide in seiner Position verankert ist.
Page 22
All manuals and user guides at all-guides.com STÖRUNGS-BEHEBUNG Im Falle einer Funktionsstörung ist das Gerät sofort auszuschalten. Nachfolgend einige Hinweise zur Behebung von einfachen Störungen. STÖRUNG URSACHE 1. Das Klimagerät funktioniert nicht. - Stromversorgung fehlerhaft/ggf. Sicherung austaushen. - Netzstecker nicht eingesteckt. - Falls die Störung nach diesen Kontrollen weiterhin besteht sollte der Installateur benachrichtigt werden.
Page 23
Prima di utilizzare il condizionatore, leggere attentamente le presenti istruzioni. Conservarle per ogni evenienza futura. UNITA' DEL VENTILATORE AD ACQUA FREDDA CONDIZIONATORE D'ARIA DEK TIPO DIVISO DA INCASTRO NEL SOFFITTO MODELLO CC10CW/MCC010CW CC30CW/MCC030CW CC15CW/MCC015CW CC40CW/MCC040CW CC20CW/MCC020CW CC50CW/MCC050CW CC25CW/MCC025CW CC60CW/MCC060CW Part No.: A08019025463 IM-CCCW-1100 (1)-McQuay...
Page 24
All manuals and user guides at all-guides.com SOMMARIO - Disegni e Dimensioni pag. i-ii - Norme Di Sicurezza pag. 2 - Schema d'Installazione pag. 3 - Installazione Dell’unità Interna pag. 3 - Allacciamenti Elettrici pag. 3 - Collegamento Della Tubatura D'acqua pag.
Page 25
1326 1526 L (mm) ALLACIAMENTI ELETTRICI CC10CW - CC25CW MODELLO CC 10CW CC 15CW CC 20CW CC 25CW Voltaggi ammessi 220V – 240V / 1Ph / 50Hz + ! o 208V – 230V / 1Ph / 60Hz + ! Fusibili consigliati...
Page 26
All manuals and user guides at all-guides.com CC28CW - CC60CW MODELLO CC 28 / 30CW CC 38 / 40 CW CC 50CW CC 60CW Voltaggi ammessi 220V – 240V / 1Ph / 50Hz + ! o 208V – 230V / 1Ph / 60Hz + ! Fusibili consigliati Dimensioni del cavetto di alimentazione Numero dei fili...
Page 27
All manuals and user guides at all-guides.com CC10CW~CC25CW (con il controllore netware-1) FCU 1 FCU 2 FCU 3 COMP L COMP L COMP L Valvola di solenoide per una valvola di 3 modi Raffreddatore x1, x2, x3 Relè (220-240V, 10A) VERIFICA GENERALE Assicurarsi con cura il seguente: - 1) L'unità...
Page 28
All manuals and user guides at all-guides.com GUASTI E RIPARAZIONI Non appena si nota che il condizionatore funziona male, spegnerlolo immediatamente. Qui di seguito, sono elencati alcuni guasti minori con le relative cause. Guasto Origine 1. Il condizionatore non funziona. - Interruzione della corrente o fusibile bruciato.
Page 29
Por favor, antes de usar su equipo de aire acondicionado, lea cuidadosamwnte este manual de instrucciones, y consérvelo para futuras consultas. SERPENTÍN DE VENTILADOR DE AGUA FRÍA ACONDICIONADOR DE AIRE EMPOTRADO EN EL TECHO TIPO SPLIT MODELO CC10CW/MCC010CW CC30CW/MCC030CW CC15CW/MCC015CW CC40CW/MCC040CW CC20CW/MCC020CW CC50CW/MCC050CW CC25CW/MCC025CW CC60CW/MCC060CW Part No.: A08019025463 IM-CCCW-1100 (1)-McQuay...
Page 30
All manuals and user guides at all-guides.com INDICE - Esquema y Dimensiones página i-ii - Precauciones de Seguridad página 2 - Esquema de Instalación página 3 - Instalación de la Unidad de Interior página 3 - Conexión del Eléctrico página 3 - Conexión de Tubos de Agua página 4 - Conexiones Eléctricas...
Page 31
1526 L (mm) CONEXIÓN DEL ELÉCTRICO CC10CW - CC25CW MODELO CC 10CW CC 15CW CC 20CW CC 25CW Margen de la tensión 220V – 240V / 1Ph / 50Hz + ! o 208V – 230V / 1Ph / 60Hz + ! Fusible recomendado Tamaño del cable de alimentación...
Page 32
All manuals and user guides at all-guides.com CC28CW - CC60CW Margen de la tensión CC 28 / 30CW CC 38 / 40 CW CC 50CW CC 60CW Voltage Range 220V – 240V / 1Ph / 50Hz + ! o 208V – 230V / 1Ph / 60Hz + ! Fusible recomendado Tamaño del cable de alimentación Número de conductores...
Page 33
All manuals and user guides at all-guides.com CC10CW~CC25CW (Con 1 controlador Netware) FCU 1 FCU 2 FCU 3 COMP L COMP L COMP L Válvula de solenoide para la válvula de 3 maneras Congelador x1, x2, x3 Relais (220-240V, 10A) COMPROBACIÓN GENERAL Asegurarse de lo siguiente, en particular que:- 1) La unidad se ha montado correctamente y que queda rígida.
Page 34
All manuals and user guides at all-guides.com LOCALIZACÓN DE AVERIAS Cuando detecte alguna anomalia en el funcionamiento de la unidad de aire acondicionado, desconéctela inmediatamente de la fuente de alimentación eléctrica. Como unas simples pistas para el mantenimiento y las reparaciones, compruebe los siguientes fallos y sus causas. FALLA CAUSA 1.
Page 35
Перед использованием Вашего кондиционера, прочитайте, пожалуйста, внимательно данное руководство по эксплуатации и сохраните его для обращения за справками в будущем. ВОДЯНОЕ ОХЛАЖДЕНИЕ ВЕНТИЛЯТОРА ДВУХКАМЕРНЫЙ ВСТРАИВАЕМЫЙ ПОТОЛОЧНЫЙ КОНДИЦИОНЕР МOДOЛЬ CC10CW/MCC010CW CC30CW/MCC030CW CC15CW/MCC015CW CC40CW/MCC040CW CC20CW/MCC020CW CC50CW/MCC050CW CC25CW/MCC025CW CC60CW/MCC060CW Part No.: A08019025463 IM-CCCW-1100 (1)-McQuay...
Page 36
All manuals and user guides at all-guides.com СОДЕРЖАНИЕ - Схема и Pазмеры страница i-ii - Меры Предосторожности страница 2 - Схема Установки страница 3 - Установка Kомнатного Блока страница 3 - Элeктрическая Сxeма страница 3 - Подключение Tрубопроводов Воды страница 4 - Подключение...
Page 37
1326 1526 L (мм) ЭЛЕКТРИЧЕCKAЯ CXEMA CC10CW - CC25CW МOДOЛЬ CC 10CW CC 15CW CC 20CW CC 25CW 220V – 240V / 1Ph / 50Hz + ! или 208V – 230V / 1Ph / 60Hz + ! Диапазон напряжения Рекомендуемый предохранитель...
Page 38
All manuals and user guides at all-guides.com CC28CW - CC60CW МOДOЛЬ CC 28 / 30CW CC 38 / 40 CW CC 50CW CC 60CW 220V – 240V / 1Ph / 50Hz + ! или 208V – 230V / 1Ph / 60Hz + ! Диапазон...
Page 39
All manuals and user guides at all-guides.com CC10CW~CC25CW ( С контроллером Netware-1 FCU 1 FCU 2 FCU 3 COMP L COMP L COMP L Solenoid Valve for 3 way valve Электромагнитный клапан для трехходового Chiller Холодильник x1, x2, x3 Реле Relay (220-240V, 10A) ОбЩААЯ...
Page 40
All manuals and user guides at all-guides.com МЕРЫ ПО УСТРАНЕНИЮ При обнаружении сбоев в работе кондиционера, немедленно выключите питание сети блока. Проверьте нижеследующие признаки неисправностей, причины и советы простейших мер по устранению. Пpичины Нeиcпpaвнocть 1. Кондиционер не работает. - Отсутствие сетевого питания или требуется замена предохранителя.
Page 41
All manuals and user guides at all-guides.com MEMO...
Page 42
All manuals and user guides at all-guides.com MEMO...
Page 43
All manuals and user guides at all-guides.com...
Page 44
All manuals and user guides at all-guides.com • In the event that there is any conflict in the interpretation of this manual and any translation of the same in any language, the English version of this manual shall prevail. • The manufacturer reserves the right to revise any of the specification and design contain herein at any time without prior notification.
Page 55
All manuals and user guides at all-guides.com...
Page 56
All manuals and user guides at all-guides.com Æ…bzU ë w¼ W¹eOKJ½ô« W Më ÊuJð ¨X½U WGà W¹QÐ UN H½ WLłd²Ã« w ·ö²š« Í«Ë VO²Jë «c¼ dO Hð w ÷—UFð Í« ÀbŠ «–« • Æo³ —UFý≈ ÊËœ s XÁË Í« w UM¼ …œułu UH «u W¹«Ë...