3.1 User Interface
1
2
3
Displays the welding current during welding, displays the adjusted current when the machine doesn't
Current Display
weld.
1
İs used for adjusting the welding current a range of 5-350A.
Current Adjustment Pot
2
Displays the open circuit voltage and the welding voltage during welding.
Voltage Display
3
İs used for a better ignition in stick electrode welding.
Hot Start Adjustment Pot
4
Light when rutile electrode welding mode is selected.
Rutile Electrode Welding Led
5
Light when basic electrode welding mode is selected.
Basic Electrode Welding Led
6
Light when cellulosiz electrode welding mode is selected.
Cellulosiz Electrode Welding Led
7
Light when touch-scratch TIG welding mode is selected.
Touch-Scratch TIG Welding Led
8
It is used to select one of the MMA and touch-scratch TIG welding modes or to access the VRD
Welding Mode Selection Button/ VRD Function
function.
You have to press and hold this button for 3 seconds to access the VRD function.
If you want to activate the VRD function, you must turn the pot 2 (Current Adjustment Pot) and turn
9
the VRD function to On position.In this way, the output current voltage drops below 12 Volts.