Les langues disponibles

Les langues disponibles

VENTILATION
OPERATION
103911
All manuals and user guides at all-guides.com
4. Open propane supply valve on propane tank(s) slowly. Note: If not opened
slowly, excess-flow check valve on propane tank may stop gas flow. If this
happens, close propane supply valve and open again slowly.
5. Check all connections for leaks. Apply mixture of liquid soap and water to gas
joints. Bubbles forming show a leak that must be corrected.
Never use an open flame to check for a leak. Apply a mix-
ture of liquid soap and water to all joints. Bubbles forming
show a leak that must be corrected. Correct all leaks at
once.
6. Close propane supply valve.
Provide at least a 1.5 square foot (0.14 square meters) open-
ing of fresh, outside air while running heater. If proper fresh,
outside air ventilation is not provided, carbon monoxide
poisoning can occur. Provide proper fresh, outside air
ventilation before running heater.
Review and understand the warnings in the Safety Informa-
tion section, pages 2 and 3. They are needed to safely
operate this heater. Follow all local codes when using this
heater.
To Start Heater
1. Follow all installation, ventilation, and safety information.
2. Locate heater on stable and level surface. Make sure strong drafts do not blow
into front or rear of heater.
3. Plug power cord of heater into a three-prong, grounded extension cord.
Extension cord must be at least six feet long. Extension cord must be UL/
CSA listed.
Extension Cord Wire Size Requirements
Up to 50 feet (15 m)long, use 18 AWG rated cord.
51 to 100 feet (16 to 30 m) long, use 16 AWG rated cord.
101 to 200 feet (31 to 60 m) long, use 14 AWG rated cord.
4. Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded outlet. Motor
will start. Fan will turn, forcing air out front of heater.
!