POWER CONNECTIONS
A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine's plug. Before connecting the
machine to the power line, make sure the switch (s) is in the "OFF" position and be sure that the electric current is of the
same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the machine.
SHOCK HAZARD. DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN
DAMP LOCAT I O N S .
GROUNDING INSTRUCTIONS
SHOCK HAZARD. THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE
OPERATOR FROM ELECTRIC SHOCK.
Your machine is wired for 120 Volt, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the "OFF" position.
1. All grounded, cord-connected machines:
In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is equipped
with an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into a matching outlet that is properly installed and
grounded in accordance with all local codes and
o r d i n a n c e s .
Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
I m p r o p e r c o n n e c t i o n o f t h e e q u i p m e n t - g r o u n d i n g
c o n d u c t o r c a n r e s u l t i n r i s k o f e l e c t r i c s h o c k . T h e
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if the
g r o u n d i n g i n s t r u c t i o n s a r e n o t completely understood, o r i f
i n d o u b t a s t o w h e t h e r t h e m a c h i n e is properly grounded.
Use only 3-wire extension cords that have 3-prong
grounding type plugs and matching 3-c o n d u c t o r
receptacles that accept the machine's plug, as shown in
Fig. A .
Repair or replace damaged or worn cord immediately.
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
Fig. A
All manuals and user guides at all-guides.com
2. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating less
than 150 volts:
If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. A, t h e
machine will have a grounding plug that looks like the plug
illustrated in F i g . A. A temporary adapter, which looks like
the adapter illustrated in Fig. B, may be used to connect
this plug to a matching 2-conductor receptacle as shown in
Fig. B if a properly grounded outlet is not available. T h e
temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician.
The green-colored rigid ear, lug, and the like, extending
from the adapter must be connected to a permanent
ground such as a properly grounded outlet box. W h e n e v e r
t h e a d a p t e r i s used, it must be held in place with a metal
s c r e w.
N O T E : In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.
6
SHOCK HAZARD. IN A L L C A S E S , M A K E
C E R TAIN THAT THE RECEPTA C L E I N
Q U E S T I O N I S P R O P E R LY G R O U N D E D . I F
Y O U A R E N O T S U R E , H AV E A Q U A L I F I E D
E L E C T R I C I A N C H E C K T HE REC E P TA C L E .
GROUNDED OUTLET BOX
GROUNDING
MEANS
ADAPTER
Fig. B